paper-with-me

홈 › Papers

The method of the approximate inverse for limited-angle CT

2025-10-05 · Bernadette Hahn, Gael Rigaud, Richard Schmähl arxiv

Limited-angle computerized tomography stands for one of the most difficult challenges in imaging. Although it opens the way to faster data acquisition in industry and less dangerous scans in medicine, standard approaches, such as the filtered backprojection (FBP) algorithm or the widely used total-variation functional, often produce various artefacts that hinder the diagnosis. With the rise of deep learning, many modern techniques have proven themselves successful in removing such artefacts but at the cost of large datasets. In this paper, we propose a new model-driven approach based on the method of the approximate inverse, which could serve as new starting point for learning strategies in the future. In contrast to FBP-type approaches, our reconstruction step consists in evaluating linear functionals on the measured data using reconstruction kernels that are precomputed as solution of an auxiliary problem. With this problem being uniquely solvable, the derived limited-angle reconstruction kernel (LARK) is able to fully reconstruct the object without the well-known streak artefacts, even for large limited angles. However, it inherits severe ill-conditioning which leads to a different kind of artefacts arising from the singular functions of the limited-angle Radon transform. The problem becomes particularly challenging when working on semi-discrete (real or analytical) measurements. We develop a general regularization strategy, named constrained limited-angle reconstruction kernel (CLARK), by combining spectral filter, the method of the approximate inverse and custom edge-preserving denoising in order to stabilize the whole process. We further derive and interpret error estimates for the application on real, i.e. semi-discrete, data and we validate our approach on synthetic and real data.

📄 PDF Abstract BibTeX arXiv:2510.04369

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

LRIP-Net: Low-Resolution Image Prior based Network for Limited-Angle CT Reconstruction

2022-07-30 · Qifeng Gao, Rui Ding, Linyuan Wang, Bin Xue 외

In the practical applications of computed tomography imaging, the projection data may be acquired within a limited-angle range and corrupted by noises due to the limitation of scanning conditions. The noisy incomplete pr…

CT Reconstruction

Probabilistic inverse optimal control for non-linear partially observable systems disentangles perceptual uncertainty and behavioral costs

2023-03-29 · NeurIPS 2023 11 · Dominik Straub, Matthias Schultheis, Heinz Koeppl, Constantin A. Rothkopf

Inverse optimal control can be used to characterize behavior in sequential decision-making tasks. Most existing work, however, is limited to fully observable or linear systems, or requires the action signals to be known.…

Active LearningDecision MakingDecision Making Under UncertaintyImitation Learning+1

DRIP: Deep Regularizers for Inverse Problems

2023-03-30 · Moshe Eliasof, Eldad Haber, Eran Treister

In this paper we consider inverse problems that are mathematically ill-posed. That is, given some (noisy) data, there is more than one solution that approximately fits the data. In recent years, deep neural techniques th…

DeblurringImage Deblurringvalid

Masked Sinogram Model with Transformer for ill-Posed Computed Tomography Reconstruction: a Preliminary Study

2022-09-03 · Zhengchun Liu, Rajkumar Kettimuthu, Ian Foster

Computed Tomography (CT) is an imaging technique where information about an object are collected at different angles (called projections or scans). Then the cross-sectional image showing the internal structure of the sli…

Computed Tomography (CT)CT ReconstructionSentence

Data-Efficient Limited-Angle CT Using Deep Priors and Regularization

2025-02-17 · Ilmari Vahteristo, Zhi-Song Liu, Andreas Rupp

Reconstructing an image from its Radon transform is a fundamental computed tomography (CT) task arising in applications such as X-ray scans. In many practical scenarios, a full 180-degree scan is not feasible, or there i…

Computed Tomography (CT)