paper-with-me

Papers

Thyristor Voltage Equalizing Network for Crowbar Application

2018-04-25

Many high voltage applications are realized with series connected thyristors. Voltage imbalance among series connected thyristors during steady state as well as in transients is one of the major concerns. This voltage imbalance is mitigated by using static and dynamic balancing network. Dynamic balancing networks are typically designed based on reverse recovery charge of the thyristor during turn-off, which suits many applications. But this is not the case for a crowbar application, where turn-off of the thyristor is not a major circuit constraint. This paper proposes the design method for dynamic balancing network considering gate turn-on delay time and the balancing network component tolerances. The paper derives two models for the dynamic balancing network based on its charge-discharge cycle. The importance of charge-discharge cycle in the design of dynamic balancing network during high di/dt operation is emphasized. Influence of dynamic balancing resistance and crowbar current limiting inductance on voltage imbalance, charging current and discharging current is studied using the analytical model. The proposed design method also offers flexibility to incorporate differences in propagation delays among the thyristor drivers that are used to trigger individual thyristors. Such delays cannot be directly incorporated in the conventional balancing network design method based on reverse recovery. Further, it is also analytically shown that designing the dynamic balancing network based on reverse recovery charge makes the balancing network lossy and bulky for crowbar application. Simulation studies and experimental results on a 12kV , 1kA crowbar consisting of six series connected thyristors confirms the theoretical analysis and validates the proposed approach for crowbar applications.

📄 PDF Abstract BibTeX arXiv:1802.06929

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

Microwave Tube Fault-Current Model for Design of Crowbar Protection

2018-02-20

Many applications that use high energy plasma are realized using Microwave tubes (MWT) that operate at peak power in the range of hundreds of MW and frequency in GHz. One failure mode of the MWT is due to the excess ener…

Reducing Harmonic Distortion in a 5-Level Cascaded H-bridge Inverter Fed by a 12-Pulse Thyristor Rectifier

2021-04-19 · Milad Sadoughi, Amirhossein Pourdadashnia, Mohammad Farhadi-Kangarlu, Sadjad Galvani

This paper investigates a multilevel inverter with a capability that produces a wide voltage range with high quality. The selective harmonic elimination (SHE) method is considered for a single-phase 5-level cascaded H-br…

Optimal Switching of Controlled Rectifiers

2020-02-25

This paper discusses a linear programming approach for designing switching signals for controlled rectifiers to achieve a low input current & output voltage total harmonic distortions. The focus here is on fully controll…

A Grid-Forming HVDC Series Tapping Converter Using Extended Techniques of Flex-LCC

2025-02-09 · Qianhao Sun, Ruofan Li, Jichen Wang, Mingchao Xia 외

This paper discusses an extension technology for the previously proposed Flexible Line-Commutated Converter (Flex LCC) [1]. The proposed extension involves modifying the arm internal-electromotive-force control, redesign…

Analytical models and estimations for a meander line turn protecting against an ultrawide band pulse

2021-04-30 · Roman Surovtsev, Alexander Nosov, Talgat Gazizov

The paper presents analytical models for calculating the response to a pulse excitation in a turn of a meander line. One of the models was used to derive a condition for equalizing the voltage amplitudes for three pulses…