WIA-LD2ND: Wavelet-based Image Alignment for Self-supervised Low-Dose CT Denoising
In clinical examinations and diagnoses, low-dose computed tomography (LDCT) is crucial for minimizing health risks compared with normal-dose computed tomography (NDCT). However, reducing the radiation dose compromises the signal-to-noise ratio, leading to degraded quality of CT images. To address this, we analyze LDCT denoising task based on experimental results from the frequency perspective, and then introduce a novel self-supervised CT image denoising method called WIA-LD2ND, only using NDCT data. The proposed WIA-LD2ND comprises two modules: Wavelet-based Image Alignment (WIA) and Frequency-Aware Multi-scale Loss (FAM). First, WIA is introduced to align NDCT with LDCT by mainly adding noise to the high-frequency components, which is the main difference between LDCT and NDCT. Second, to better capture high-frequency components and detailed information, Frequency-Aware Multi-scale Loss (FAM) is proposed by effectively utilizing multi-scale feature space. Extensive experiments on two public LDCT denoising datasets demonstrate that our WIA-LD2ND, only uses NDCT, outperforms existing several state-of-the-art weakly-supervised and self-supervised methods. Source code is available at https://github.com/zhaohaoyu376/WI-LD2ND.
Code (1)
Tasks
DenoisingImage DenoisingMethods 이 논문이 사용한 방법론
Similar Papers 제목 키워드 기반
A deep convolutional neural network using directional wavelets for low-dose X-ray CT reconstruction
Due to the potential risk of inducing cancers, radiation dose of X-ray CT should be reduced for routine patient scanning. However, in low-dose X-ray CT, severe artifacts usually occur due to photon starvation, beamharden…
CT ReconstructionDenoisingLow-Dose X-Ray Ct ReconstructionWavelet Domain Residual Network (WavResNet) for Low-Dose X-ray CT Reconstruction
Model based iterative reconstruction (MBIR) algorithms for low-dose X-ray CT are computationally complex because of the repeated use of the forward and backward projection. Inspired by this success of deep learning in co…
CT ReconstructionLow-Dose X-Ray Ct ReconstructionMDAA-Diff: CT-Guided Multi-Dose Adaptive Attention Diffusion Model for PET Denoising
Acquiring high-quality Positron Emission Tomography (PET) images requires administering high-dose radiotracers, which increases radiation exposure risks. Generating standard-dose PET (SPET) from low-dose PET (LPET) has b…
DenoisingDiagnosticWindow-Level is a Strong Denoising Surrogate
CT image quality is heavily reliant on radiation dose, which causes a trade-off between radiation dose and image quality that affects the subsequent image-based diagnostic performance. However, high radiation can be harm…
DenoisingDiagnosticImage DenoisingSelf-Supervised LearningNo-reference denoising of low-dose CT projections
Low-dose computed tomography (LDCT) became a clear trend in radiology with an aspiration to refrain from delivering excessive X-ray radiation to the patients. The reduction of the radiation dose decreases the risks to th…
DenoisingDiagnostic