3D Convolutional Encoder-Decoder Network for Low-Dose CT via Transfer Learning from a 2D Trained Network
Low-dose computed tomography (CT) has attracted a major attention in the medical imaging field, since CT-associated x-ray radiation carries health risks for patients. The reduction of CT radiation dose, however, compromises the signal-to-noise ratio, and may compromise the image quality and the diagnostic performance. Recently, deep-learning-based algorithms have achieved promising results in low-dose CT denoising, especially convolutional neural network (CNN) and generative adversarial network (GAN). This article introduces a Contracting Path-based Convolutional Encoder-decoder (CPCE) network in 2D and 3D configurations within the GAN framework for low-dose CT denoising. A novel feature of our approach is that an initial 3D CPCE denoising model can be directly obtained by extending a trained 2D CNN and then fine-tuned to incorporate 3D spatial information from adjacent slices. Based on the transfer learning from 2D to 3D, the 3D network converges faster and achieves a better denoising performance than that trained from scratch. By comparing the CPCE with recently published methods based on the simulated Mayo dataset and the real MGH dataset, we demonstrate that the 3D CPCE denoising model has a better performance, suppressing image noise and preserving subtle structures.
Code (0)
등록된 구현이 없습니다.
Tasks
Computed Tomography (CT)DecoderDenoisingDiagnosticGenerative Adversarial NetworkTransfer LearningMethods 이 논문이 사용한 방법론
Similar Papers 제목 키워드 기반
Improving Electron Micrograph Signal-to-Noise with an Atrous Convolutional Encoder-Decoder
We present an atrous convolutional encoder-decoder trained to denoise 512$\times$512 crops from electron micrographs. It consists of a modified Xception backbone, atrous convoltional spatial pyramid pooling module and a …
DecoderPlaying the Game of 2048Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN)
Given the potential X-ray radiation risk to the patient, low-dose CT has attracted a considerable interest in the medical imaging field. The current main stream low-dose CT methods include vendor-specific sinogram domain…
DecoderLesion DetectionHigh-quality Low-dose CT Reconstruction Using Convolutional Neural Networks with Spatial and Channel Squeeze and Excitation
Low-dose computed tomography (CT) allows the reduction of radiation risk in clinical applications at the expense of image quality, which deteriorates the diagnosis accuracy of radiologists. In this work, we present a Hig…
Computed Tomography (CT)CT ReconstructionDecoderImage ReconstructionA Cascade Transformer-based Model for 3D Dose Distribution Prediction in Head and Neck Cancer Radiotherapy
Radiation therapy is the primary method used to treat cancer in the clinic. Its goal is to deliver a precise dose to the planning target volume (PTV) while protecting the surrounding organs at risk (OARs). However, the t…
DecoderSegmentationGenerative Models Improve Radiomics Performance in Different Tasks and Different Datasets: An Experimental Study
Radiomics is an active area of research focusing on high throughput feature extraction from medical images with a wide array of applications in clinical practice, such as clinical decision support in oncology. However, n…
Computed Tomography (CT)DecoderDeep AttentionDenoising+3