paper-with-me

Papers

Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN)

2017-02-01 · Hu Chen, Yi Zhang, Mannudeep K. Kalra, Feng Lin, Yang Chen, Peixi Liao, Jiliu Zhou, Ge Wang

Given the potential X-ray radiation risk to the patient, low-dose CT has attracted a considerable interest in the medical imaging field. The current main stream low-dose CT methods include vendor-specific sinogram domain filtration and iterative reconstruction, but they need to access original raw data whose formats are not transparent to most users. Due to the difficulty of modeling the statistical characteristics in the image domain, the existing methods for directly processing reconstructed images cannot eliminate image noise very well while keeping structural details. Inspired by the idea of deep learning, here we combine the autoencoder, the deconvolution network, and shortcut connections into the residual encoder-decoder convolutional neural network (RED-CNN) for low-dose CT imaging. After patch-based training, the proposed RED-CNN achieves a competitive performance relative to the-state-of-art methods in both simulated and clinical cases. Especially, our method has been favorably evaluated in terms of noise suppression, structural preservation and lesion detection.

📄 PDF Abstract BibTeX arXiv:1702.00288

Code (1)

SSinyu/RED_CNN pytorch

Tasks

DecoderLesion Detection

Similar Papers 제목 키워드 기반

Improving Electron Micrograph Signal-to-Noise with an Atrous Convolutional Encoder-Decoder

2018-07-30 · Jeffrey M. Ede

We present an atrous convolutional encoder-decoder trained to denoise 512$\times$512 crops from electron micrographs. It consists of a modified Xception backbone, atrous convoltional spatial pyramid pooling module and a …

DecoderPlaying the Game of 2048

High-quality Low-dose CT Reconstruction Using Convolutional Neural Networks with Spatial and Channel Squeeze and Excitation

2021-04-01 · Jingfeng Lu, Shuo Wang, Ping Li, Dong Ye

Low-dose computed tomography (CT) allows the reduction of radiation risk in clinical applications at the expense of image quality, which deteriorates the diagnosis accuracy of radiologists. In this work, we present a Hig…

Computed Tomography (CT)CT ReconstructionDecoderImage Reconstruction

3D Convolutional Encoder-Decoder Network for Low-Dose CT via Transfer Learning from a 2D Trained Network

2018-02-15 · Hongming Shan, Yi Zhang, Qingsong Yang, Uwe Kruger 외

Low-dose computed tomography (CT) has attracted a major attention in the medical imaging field, since CT-associated x-ray radiation carries health risks for patients. The reduction of CT radiation dose, however, compromi…

Computed Tomography (CT)DecoderDenoisingDiagnostic+2

A Cascade Transformer-based Model for 3D Dose Distribution Prediction in Head and Neck Cancer Radiotherapy

2023-07-22 · Tara Gheshlaghi, Shahabedin Nabavi, Samire Shirzadikia, Mohsen Ebrahimi Moghaddam 외

Radiation therapy is the primary method used to treat cancer in the clinic. Its goal is to deliver a precise dose to the planning target volume (PTV) while protecting the surrounding organs at risk (OARs). However, the t…

DecoderSegmentation

Residual Encoder-Decoder Network for Deep Subspace Clustering

2019-10-12 · Shuai Yang, Wenqi Zhu, Yuesheng Zhu

Subspace clustering aims to cluster unlabeled data that lies in a union of low-dimensional linear subspaces. Deep subspace clustering approaches based on auto-encoders have become very popular to solve subspace clusterin…

ClusteringDecoder