3D Reconstruction with Low Resolution, Small Baseline and High Radial Distortion Stereo Images
In this paper we analyze and compare approaches for 3D reconstruction from low-resolution (250x250), high radial distortion stereo images, which are acquired with small baseline (approximately 1mm). These images are acquired with the system NanEye Stereo manufactured by CMOSIS/AWAIBA. These stereo cameras have also small apertures, which means that high levels of illumination are required. The goal was to develop an approach yielding accurate reconstructions, with a low computational cost, i.e., avoiding non-linear numerical optimization algorithms. In particular we focused on the analysis and comparison of radial distortion models. To perform the analysis and comparison, we defined a baseline method based on available software and methods, such as the Bouguet toolbox [2] or the Computer Vision Toolbox from Matlab. The approaches tested were based on the use of the polynomial model of radial distortion, and on the application of the division model. The issue of the center of distortion was also addressed within the framework of the application of the division model. We concluded that the division model with a single radial distortion parameter has limitations.
Code (0)
등록된 구현이 없습니다.
Tasks
3D ReconstructionSimilar Papers 제목 키워드 기반
ReconResNet: Regularised Residual Learning for MR Image Reconstruction of Undersampled Cartesian and Radial Data
MRI is an inherently slow process, which leads to long scan time for high-resolution imaging. The speed of acquisition can be increased by ignoring parts of the data (undersampling). Consequently, this leads to the degra…
compressed sensingImage ReconstructionSSIMDeep Learning with Domain Adaptation for Accelerated Projection-Reconstruction MR
Purpose: The radial k-space trajectory is a well-established sampling trajectory used in conjunction with magnetic resonance imaging. However, the radial k-space trajectory requires a large number of radial lines for hig…
compressed sensingComputed Tomography (CT)Deep LearningDomain AdaptationKam method for Cryo-EM particle reconstruction
The Cryo-EM 3D particle reconstruction is essential for identifying protein and uncover the biological mechanism of the macro-molecules. In this paper, we use Kam method for reconstruction. Kam method is \textit{ab-initi…
Accelerated Dynamic Magnetic Resonance Imaging from Spatial-Subspace Reconstructions (SPARS)
Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) ideally requires a high spatial and high temporal resolution, but hardware limitations prevent acquisitions from simultaneously achieving both. Existing im…
Image ReconstructionSubspace Implicit Neural Representations for Real-Time Cardiac Cine MR Imaging
Conventional cardiac cine MRI methods rely on retrospective gating, which limits temporal resolution and the ability to capture continuous cardiac dynamics, particularly in patients with arrhythmias and beat-to-beat vari…
Diagnostic