paper-with-me

홈 › Papers

A Comparative Analysis of Transformer-less Inverter Topologies for Grid-Connected PV Systems: Minimizing Leakage Current and THD

2025-01-14 · Shashwot Shrestha, Rachana Subedi, Swodesh Sharma, Sushil Phuyal, Indraman Tamrakar

The integration of distributed energy resources (DERs), particularly photovoltaic (PV) systems, into power grids has gained major attention due to their environmental and economic benefits. Although traditional transformer-based grid-connected PV inverters provide galvanic isolation for leakage current, they suffer from major drawbacks of high cost, lower efficiency, and increased size. Transformer-less grid-connected PV inverters (TLGI) have emerged as a prominent alternative, as they achieve higher efficiency, compact design, and lower cost. However, due to a lack of galvanic isolation, TLGIs are highly affected by leakage current caused by the fluctuation of common-mode voltage (CMV). This paper investigates three topologies H4, H5, and HERIC with comparisons between their CMV, differential-mode voltage (DMV), total harmonic distortion (THD), and leakage current. A simulation was conducted for each topology in MATLAB/Simulink R2023a, and the results demonstrate that the H5 topology achieves a balance between low leakage current, reduced THD, and optimal operational efficiency, making it suitable for practical application.

📄 PDF Abstract BibTeX arXiv:2501.08103

Code (0)

등록된 구현이 없습니다.

Methods 이 논문이 사용한 방법론

Softmax The Softmax output function transforms a previous layer's output into a vector of probabilities. It is commonly used for multiclass classification. Given an input vector $x$…
Attention 설명 없음

Similar Papers 제목 키워드 기반

A Novel SEPIC-Ćuk Based High Gain Solar Micro-Inverter for Grid Integration

2021-06-03 · Arup Ratan Paul, Arghyadip Bhattacharya, Kishore Chatterjee

Solar micro-inverters are becoming increasingly popular as they are modular, and they posses the capability of extracting maximum available power from the individual photovoltaic (PV) modules of a solar array. For realiz…

Comparative Analysis of Conventional and Modified H-Bridge Inverter Configuration

2019-08-27

In this paper, a comparative analysis is presented for conventional and modified H Bridge configuration of 5 and 7 level inverter. A modified H Bridge converter utilizes a reduced number of switches for the same level ou…

Design Methodology for a Medium Voltage Single Stage LLC Resonant Solar PV Inverter

2023-10-05 · Parthkumar Bhuvela, Hooman Taghavi, Adel Nasiri

An inverter is generally employed with MV LFT to connect to the grid in a grid-tied PV system. However, in some single-stage topologies, the LFTs are replaced by HFT combined with an unfolder inverter. Generally, these t…

Physics-Informed AI Inverter

2024-06-25 · Qing Shen, Yifan Zhou, Peng Zhang, Yacov A. Shamash 외

This letter devises an AI-Inverter that pilots the use of a physics-informed neural network (PINN) to enable AI-based electromagnetic transient simulations (EMT) of grid-forming inverters. The contributions are threefold…

Stability bounds of droop-controlled inverters in power grid networks

2023-03-29 · Philipp C. Böttcher, Leonardo Rydin Gorjão, Dirk Witthaut

The energy mix of future power systems will include high shares of wind power and solar PV. These generation facilities are generally connected via power-electronic inverters. While conventional generation responds dynam…