paper-with-me

홈 › Papers

A Pure Integral-Type PLL with a Damping Branch to Enhance the Stability of Grid-Tied Inverter under Weak Grids

2024-01-04 · Yi Zhou, Zhouchen Deng, Shi Chen, Yiwei Qiu, Tianlei Zang, Buxiang Zhou

In a phase-locked loop (PLL) synchronized inverter, due to the strong nonlinear coupling between the PLL's parame-ters and the operation power angle, the equivalent damping coefficient will quickly deteriorate while the power angle is close to 90{\deg} under an ultra-weak grid, which causes the synchronous instability. To address this issue, in this letter, a pure integral-type phase-locked loop (IPLL) with a damping branch is proposed to replace the traditional PI-type PLL. The equivalent damping coefficient of an IPLL-synchronized inverter is decoupled with the steady-state power angle. As a result, the IPLL-synchronized inverter can stably operate under an ultra-weak grid when the equilibrium point exists. Finally, time-domain simulation results verify the effectiveness and correctness of the proposed IPLL.

📄 PDF Abstract BibTeX arXiv:2401.02202

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

New perspectives on transient stability between grid-following and grid-forming VSCs

2022-07-07 · Kaizhe Zhang

The grid-following and grid-forming controls in voltage-source converters are considered as different operation modes and the synchronization mechanism of them are studied separately. In this article, the intrinsic relat…

Self-Adaptive Active Damping Method for Stability Enhancement of Systems With Black-Box Inverters Considering Operating Points

2024-11-28 · Yang Li, Xiangyang Wu, Zhikang Shuai, Junbin Fang 외

Due to the black-box nature of inverters and the wide variation range of operating points, it is challenging to on-line predict and adaptively enhance the stability of inverter-based systems. To solve this problem, this …

A Sensorised Lattice Footplate for a Semi-Active Prosthetic Foot

2026-06-24 · Jinze Ge, Jingcheng Sun, Chengxu Zhou arxiv

This paper investigates whether magnetic plantar sensing can be embedded directly inside the load-bearing compliant element of a low-cost semi-active prosthetic foot. We present a prototype integrating a sensorised 3D-pr…

Stability Enhancement of LCL-Type Grid-Following Inverters Using Capacitor Voltage Active Damping

2024-04-08 · Naser Souri, Ali Mehrizi-Sani, Kambiz Tehrani

An LCL filter offers superior attenuation for high-frequency harmonics for three-phase grid-following inverters compared to LC and L filters. However, it also introduces an inherent resonance peak, which can lead to powe…

Measurement-Based Estimation of System State Matrix for AC Power Systems with Integrated VSCs

2020-06-27 · Jinpeng Guo, Xiaozhe Wang, Boon-Teck Ooi

In this paper, a wide-area measurement system (WAMS)-based method is proposed to estimate the system state matrix for AC system with integrated voltage source converters (VSCs) and identify the electromechanical modes. T…