paper-with-me

홈 › Papers

Accuracy, Uncertainty, and Adaptability of Automatic Myocardial ASL Segmentation using Deep CNN

2018-12-10 · Hung P. Do, Yi Guo, Andrew J. Yoon, Krishna S. Nayak

PURPOSE: To apply deep CNN to the segmentation task in myocardial arterial spin labeled (ASL) perfusion imaging and to develop methods that measure uncertainty and that adapt the CNN model to a specific false positive vs. false negative tradeoff. METHODS: The Monte Carlo dropout (MCD) U-Net was trained on data from 22 subjects and tested on data from 6 heart transplant recipients. Manual segmentation and regional myocardial blood flow (MBF) were available for comparison. We consider two global uncertainty measures, named Dice Uncertainty and MCD Uncertainty, which were calculated with and without the use of manual segmentation, respectively. Tversky loss function with a hyperparameter $\beta$ was used to adapt the model to a specific false positive vs. false negative tradeoff. RESULTS: The MCD U-Net achieved Dice coefficient of mean(std) = 0.91(0.04) on the test set. MBF measured using automatic segmentations was highly correlated to that measured using the manual segmentation ($R^2$ = 0.96). Dice Uncertainty and MCD Uncertainty were in good agreement ($R^2$ = 0.64). As $\beta$ increased, the false positive rate systematically decreased and false negative rate systematically increased. CONCLUSION: We demonstrate the feasibility of deep CNN for automatic segmentation of myocardial ASL, with good accuracy. We also introduce two simple methods for assessing model uncertainty. Finally, we demonstrate the ability to adapt the CNN model to a specific false positive vs. false negative tradeoff. These findings are directly relevant to automatic segmentation in quantitative cardiac MRI and are broadly applicable to automatic segmentation problems in diagnostic imaging.

📄 PDF Abstract BibTeX arXiv:1812.03974

Code (0)

등록된 구현이 없습니다.

Tasks

DiagnosticSegmentation

Methods 이 논문이 사용한 방법론

Monte Carlo Dropout 설명 없음
Concatenated Skip Connection A Concatenated Skip Connection is a type of skip connection that seeks to reuse features by concatenating them to new layers, allowing more information to be retained from…
ReLU How Do I Communicate to Expedia? How Do I Communicate to Expedia? – Call ☎️ +1-(888) 829 (0881) or +1-805-330-4056 or +1-805-330-4056 for Live Support & Special Travel…
Max Pooling Max Pooling is a pooling operation that calculates the maximum value for patches of a feature map, and uses it to create a downsampled (pooled) feature map. It is usually…
Convolution A convolution is a type of matrix operation, consisting of a kernel, a small matrix of weights, that slides over input data performing element-wise multiplication with the…
U-Net 설명 없음
Dropout Dropout is a regularization technique for neural networks that drops a unit (along with connections) at training time with a specified probability $p$ (a common value is…

Similar Papers 제목 키워드 기반

Automatic Myocardial Infarction Evaluation from Delayed-Enhancement Cardiac MRI using Deep Convolutional Networks

2020-10-30 · Kibrom Berihu Girum, Youssef Skandarani, Raabid Hussain, Alexis Bozorg Grayeli 외

In this paper, we propose a new deep learning framework for an automatic myocardial infarction evaluation from clinical information and delayed enhancement-MRI (DE-MRI). The proposed framework addresses two tasks. The fi…

Cascaded Convolutional Neural Network for Automatic Myocardial Infarction Segmentation from Delayed-Enhancement Cardiac MRI

2020-12-28 · Yichi Zhang

Automatic segmentation of myocardial contours and relevant areas like infraction and no-reflow is an important step for the quantitative evaluation of myocardial infarction. In this work, we propose a cascaded convolutio…

Segmentation

Fully Automatic Myocardial Segmentation of Contrast Echocardiography Sequence Using Random Forests Guided by Shape Model

2018-06-19 · Yuanwei Li, Chin Pang Ho, Matthieu Toulemonde, Navtej Chahal 외

Myocardial contrast echocardiography (MCE) is an imaging technique that assesses left ventricle function and myocardial perfusion for the detection of coronary artery diseases. Automatic MCE perfusion quantification is c…

Image RegistrationImage SegmentationMedical Image SegmentationSegmentation+1

Hardware-aware Real-time Myocardial Segmentation Quality Control in Contrast Echocardiography

2021-09-14 · Dewen Zeng, Yukun Ding, Haiyun Yuan, Meiping Huang 외

Automatic myocardial segmentation of contrast echocardiography has shown great potential in the quantification of myocardial perfusion parameters. Segmentation quality control is an important step to ensure the accuracy …

Hardware Aware Neural Architecture SearchNeural Architecture SearchSegmentation

Cascaded Framework for Automatic Evaluation of Myocardial Infarction from Delayed-Enhancement Cardiac MRI

2020-12-29 · Jun Ma

Automatic evaluation of myocardium and pathology plays an important role in the quantitative analysis of patients suffering from myocardial infarction. In this paper, we present a cascaded convolutional neural network fr…

ClassificationGeneral ClassificationSegmentation