Affine Transformation Edited and Refined Deep Neural Network for Quantitative Susceptibility Mapping
Deep neural networks have demonstrated great potential in solving dipole inversion for Quantitative Susceptibility Mapping (QSM). However, the performances of most existing deep learning methods drastically degrade with mismatched sequence parameters such as acquisition orientation and spatial resolution. We propose an end-to-end AFfine Transformation Edited and Refined (AFTER) deep neural network for QSM, which is robust against arbitrary acquisition orientation and spatial resolution up to 0.6 mm isotropic at the finest. The AFTER-QSM neural network starts with a forward affine transformation layer, followed by an Unet for dipole inversion, then an inverse affine transformation layer, followed by a Residual Dense Network (RDN) for QSM refinement. Simulation and in-vivo experiments demonstrated that the proposed AFTER-QSM network architecture had excellent generalizability. It can successfully reconstruct susceptibility maps from highly oblique and anisotropic scans, leading to the best image quality assessments in simulation tests and suppressed streaking artifacts and noise levels for in-vivo experiments compared with other methods. Furthermore, ablation studies showed that the RDN refinement network significantly reduced image blurring and susceptibility underestimation due to affine transformations. In addition, the AFTER-QSM network substantially shortened the reconstruction time from minutes using conventional methods to only a few seconds.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Motion Artifact Reduction in Quantitative Susceptibility Mapping using Deep Neural Network
An approach to reduce motion artifacts in Quantitative Susceptibility Mapping using deep learning is proposed. We use an affine motion model with randomly created motion profiles to simulate motion-corrupted QSM images. …
QSMGAN: Improved Quantitative Susceptibility Mapping using 3D Generative Adversarial Networks with Increased Receptive Field
Quantitative susceptibility mapping (QSM) is a powerful MRI technique that has shown great potential in quantifying tissue susceptibility in numerous neurological disorders. However, the intrinsic ill-posed dipole invers…
Affine Correspondences in Stereo Vision: Theory, Practice, and Limitations
Affine transformations have been recently used for stereo vision. They can be exploited in various computer vision application, e.g., when estimating surface normals, homographies, fundamental and essential matrices. Eve…
3D ReconstructionSemAffiNet: Semantic-Affine Transformation for Point Cloud Segmentation
Conventional point cloud semantic segmentation methods usually employ an encoder-decoder architecture, where mid-level features are locally aggregated to extract geometric information. However, the over-reliance on these…
DecoderImage SegmentationPoint Cloud SegmentationSegmentation+1Non-locally Encoder-Decoder Convolutional Network for Whole Brain QSM Inversion
Quantitative Susceptibility Mapping (QSM) reconstruction is a challenging inverse problem driven by ill conditioning of its field-to -susceptibility transformation. State-of-art QSM reconstruction methods either suffer f…
DecoderTranslation