paper-with-me

Papers

Automated Robotic Needle Puncture for Percutaneous Dilatational Tracheostomy

2026-02-26 · Yuan Tang, Bruno V. Adorno, Brendan A. McGrath, Andrew Weightman arxiv

Percutaneous dilatational tracheostomy (PDT) is frequently performed on patients in intensive care units for prolonged mechanical ventilation. The needle puncture, as the most critical step of PDT, could lead to adverse consequences such as major bleeding and posterior tracheal wall perforation if performed inaccurately. Current practices of PDT puncture are all performed manually with no navigation assistance, which leads to large position and angular errors (5 mm and 30 degree). To improve the accuracy and reduce the difficulty of the PDT procedure, we propose a system that automates the needle insertion using a velocity-controlled robotic manipulator. Guided using pose data from two electromagnetic sensors, one at the needle tip and the other inside the trachea, the robotic system uses an adaptive constrained controller to adapt the uncertain kinematic parameters online and avoid collisions with the patient's body and tissues near the target. Simulations were performed to validate the controller's implementation, and then four hundred PDT punctures were performed on a mannequin to evaluate the position and angular accuracy. The absolute median puncture position error was 1.7 mm (IQR: 1.9 mm) and midline deviation was 4.13 degree (IQR: 4.55 degree), measured by the sensor inside the trachea. The small deviations from the nominal puncture in a simulated experimental setup and formal guarantees of collision-free insertions suggest the feasibility of the robotic PDT puncture.

📄 PDF Abstract BibTeX arXiv:2602.22952

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

A Deep Learning-Driven Autonomous System for Retinal Vein Cannulation: Validation Using a Chicken Embryo Model

2025-07-29 · Yi Wang, Peiyao Zhang, Mojtaba Esfandiari, Peter Gehlbach 외 arxiv

Retinal vein cannulation (RVC) is a minimally invasive microsurgical procedure for treating retinal vein occlusion (RVO), a leading cause of vision impairment. However, the small size and fragility of retinal veins, coup…

Contact Detection

Transformer Based Tissue Classification in Robotic Needle Biopsy

2024-09-07 · Fanxin Wang, Yikun Cheng, Sudipta S Mukherjee, Rohit Bhargava 외

Image-guided minimally invasive robotic surgery is commonly employed for tasks such as needle biopsies or localized therapies. However, the nonlinear deformation of various tissue types presents difficulties for surgeons…

Classification

A Fourier-enhanced multi-modal 3D small object optical mark recognition and positioning method for percutaneous abdominal puncture surgical navigation

2024-04-13 · Zezhao Guo, Yanzhong Guo, Zhanfang Zhao

Navigation for thoracoabdominal puncture surgery is used to locate the needle entry point on the patient's body surface. The traditional reflective ball navigation method is difficult to position the needle entry point o…

Vibration-Based Energy Metric for Restoring Needle Alignment in Autonomous Robotic Ultrasound

2025-08-09 · Zhongyu Chen, Chenyang Li, Xuesong Li, Dianye Huang 외 arxiv

Precise needle alignment is essential for percutaneous needle insertion in robotic ultrasound-guided procedures. However, inherent challenges such as speckle noise, needle-like artifacts, and low image resolution make ro…

Force-IMU Fusion-Based Sensing Acupuncture Needle and Quantitative Analysis System for Acupuncture Manipulations

2025-07-07 · Peng Tian, Kang Yu, Tianyun Jiang, Yuqi Wang 외

Acupuncture, one of the key therapeutic methods in Traditional Chinese Medicine (TCM), has been widely adopted in various clinical fields. Quantitative research on acupuncture manipulation parameters is critical to achie…