paper-with-me

Papers

Automatic 2D-3D Registration without Contrast Agent during Neurovascular Interventions

2021-06-08 · Robert Homan, René van Rijsselt, Daniel Ruijters

Fusing live fluoroscopy images with a 3D rotational reconstruction of the vasculature allows to navigate endovascular devices in minimally invasive neuro-vascular treatment, while reducing the usage of harmful iodine contrast medium. The alignment of the fluoroscopy images and the 3D reconstruction is initialized using the sensor information of the X-ray C-arm geometry. Patient motion is then corrected by an image-based registration algorithm, based on a gradient difference similarity measure using digital reconstructed radiographs of the 3D reconstruction. This algorithm does not require the vessels in the fluoroscopy image to be filled with iodine contrast agent, but rather relies on gradients in the image (bone structures, sinuses) as landmark features. This paper investigates the accuracy, robustness and computation time aspects of the image-based registration algorithm. Using phantom experiments 97% of the registration attempts passed the success criterion of a residual registration error of less than 1 mm translation and 3{\deg} rotation. The paper establishes a new method for validation of 2D-3D registration without requiring changes to the clinical workflow, such as attaching fiducial markers. As a consequence, this method can be retrospectively applied to pre-existing clinical data. For clinical data experiments, 87% of the registration attempts passed the criterion of a residual translational error of < 1 mm, and 84% possessed a rotational error of < 3{\deg}.

📄 PDF Abstract BibTeX arXiv:2106.15308

Code (0)

등록된 구현이 없습니다.

Tasks

3D ReconstructionNavigate

Similar Papers 제목 키워드 기반

3-D/2-D Registration of Cardiac Structures by 3-D Contrast Agent Distribution Estimation

2016-01-22 · Matthias Hoffmann, Christopher Kowalewski, Andreas Maier, Klaus Kurzidim 외

For augmented fluoroscopy during cardiac catheter ablation procedures, a preoperatively acquired 3-D model of the left atrium of the patient can be registered to X-ray images. Therefore the 3D-model is matched with the c…

AnatomyGPU

Adaptive Conditional Contrast-Agnostic Deformable Image Registration with Uncertainty Estimation

2026-01-09 · Yinsong Wang, Xinzhe Luo, Siyi Du, Chen Qin arxiv

Deformable multi-contrast image registration is a challenging yet crucial task due to the complex, non-linear intensity relationships across different imaging contrasts. Conventional registration methods typically rely o…

Image Registration

Structure-aware registration network for liver DCE-CT images

2023-03-08 · Peng Xue, Jingyang Zhang, Lei Ma, Mianxin Liu 외

Image registration of liver dynamic contrast-enhanced computed tomography (DCE-CT) is crucial for diagnosis and image-guided surgical planning of liver cancer. However, intensity variations due to the flow of contrast ag…

Image RegistrationSegmentation

Self-Supervised Multi-Modal Alignment for Whole Body Medical Imaging

2021-07-14 · Rhydian Windsor, Amir Jamaludin, Timor Kadir, Andrew Zisserman

This paper explores the use of self-supervised deep learning in medical imaging in cases where two scan modalities are available for the same subject. Specifically, we use a large publicly-available dataset of over 20,00…

SynthMorph: learning contrast-invariant registration without acquired images

2020-04-21 · Malte Hoffmann, Benjamin Billot, Douglas N. Greve, Juan Eugenio Iglesias 외

We introduce a strategy for learning image registration without acquired imaging data, producing powerful networks agnostic to contrast introduced by magnetic resonance imaging (MRI). While classical registration methods…

AnatomyImage Registration