Cochlear Implantation of Slim Pre-curved Arrays using Automatic Pre-operative Insertion Plans
Hypothesis: Pre-operative cochlear implant (CI) electrode array (EL) insertion plans created by automated image analysis methods can improve positioning of slim pre-curved EL. Background: This study represents the first evaluation of a system for patient-customized EL insertion planning for a slim pre-curved EL. Methods: Twenty-one temporal bone specimens were divided into experimental and control groups and underwent cochlear implantation. For the control group, the surgeon performed a traditional insertion without an insertion plan. For the experimental group, customized insertion plans guided entry site, trajectory, curl direction, and base insertion depth. An additional 35 clinical insertions from the same surgeon were analyzed, 7 of which were conducted using the insertion plans. EL positioning was analyzed using post-operative imaging auto-segmentation techniques, allowing measurement of angular insertion depth (AID), mean modiolar distance (MMD), and scalar position. Results: In the cadaveric temporal bones, 3 scalar translocations, including 2 foldovers, occurred in 14 control group insertions. In the clinical insertions, translocations occurred in 2 of 28 control cases. No translocations or folds occurred in the 7 experimental temporal bone and the 7 experimental clinical insertions. Among the non-translocated cases, overall AID and MMD were 401(41) degrees and 0.34(0.13) mm for the control insertions. AID and MMD for the experimental insertions were 424(43) degrees and 0.34(0.09) mm overall and were 432(19) and 0.30(0.07) mm for cases where the planned insertion depth was achieved. Conclusions: Trends toward improved EL positioning within scala tympani were observed when EL insertion plans are used. Variability in MMD was significantly reduced (0.07mm vs 0.13 mm, p=0.039) when the planned depth was achieved.
Code (0)
등록된 구현이 없습니다.
Methods 이 논문이 사용한 방법론
Similar Papers 제목 키워드 기반
Automatic techniques for cochlear implant CT image analysis
The goals of this dissertation are to fully automate the image processing techniques needed in the post-operative stage of IGCIP and to perform a thorough analysis of (a) the robustness of the automatic image processing …
Validation of image-guided cochlear implant programming techniques
Cochlear implants (CIs) are a standard treatment for patients who experience severe to profound hearing loss. Recent studies have shown that hearing outcome is correlated with intra-cochlear anatomy and electrode placeme…
AnatomySegmentationPredicting electrode array impedance after one month from cochlear implantation surgery
Sensorineural hearing loss can be treated using Cochlear implantation. After this surgery using the electrode array impedance measurements, we can check the stability of the impedance value and the dynamic range. Deterio…
speech-recognitionSpeech RecognitionEndoscopic vs. volumetric OCT imaging of mastoid bone structure for pose estimation in minimally invasive cochlear implant surgery
Purpose: The facial recess is a delicate structure that must be protected in minimally invasive cochlear implant surgery. Current research estimates the drill trajectory by using endoscopy of the unique mastoid patterns.…
Pose EstimationWSC-Trans: A 3D network model for automatic multi-structural segmentation of temporal bone CT
Cochlear implantation is currently the most effective treatment for patients with severe deafness, but mastering cochlear implantation is extremely challenging because the temporal bone has extremely complex and small th…
Segmentation