ConVibNet: Needle Detection during Continuous Insertion via Frequency-Inspired Features
Purpose: Ultrasound-guided needle interventions are widely used in clinical practice, but their success critically depends on accurate needle placement, which is frequently hindered by the poor and intermittent visibility of needles in ultrasound images. Existing approaches remain limited by artifacts, occlusions, and low contrast, and often fail to support real-time continuous insertion. To overcome these challenges, this study introduces a robust real-time framework for continuous needle detection. Methods: We present ConVibNet, an extension of VibNet for detecting needles with significantly reduced visibility, addressing real-time, continuous needle tracking during insertion. ConVibNet leverages temporal dependencies across successive ultrasound frames to enable continuous estimation of both needle tip position and shaft angle in dynamic scenarios. To strengthen temporal awareness of needle-tip motion, we introduce a novel intersection-and-difference loss that explicitly leverages motion correlations across consecutive frames. In addition, we curated a dedicated dataset for model development and evaluation. Results: The performance of the proposed ConVibNet model was evaluated on our dataset, demonstrating superior accuracy compared to the baseline VibNet and UNet-LSTM models. Specifically, ConVibNet achieved a tip error of 2.80+-2.42 mm and an angle error of 1.69+-2.00 deg. These results represent a 0.75 mm improvement in tip localization accuracy over the best-performing baseline, while preserving real-time inference capability. Conclusion: ConVibNet advances real-time needle detection in ultrasound-guided interventions by integrating temporal correlation modeling with a novel intersection-and-difference loss, thereby improving accuracy and robustness and demonstrating high potential for integration into autonomous insertion systems.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Needle Tip Force Estimation using an OCT Fiber and a Fused convGRU-CNN Architecture
Needle insertion is common during minimally invasive interventions such as biopsy or brachytherapy. During soft tissue needle insertion, forces acting at the needle tip cause tissue deformation and needle deflection. Acc…
Vibration-Based Energy Metric for Restoring Needle Alignment in Autonomous Robotic Ultrasound
Precise needle alignment is essential for percutaneous needle insertion in robotic ultrasound-guided procedures. However, inherent challenges such as speckle noise, needle-like artifacts, and low image resolution make ro…
Collaborative Robotic Biopsy with Trajectory Guidance and Needle Tip Force Feedback
The diagnostic value of biopsies is highly dependent on the placement of needles. Robotic trajectory guidance has been shown to improve needle positioning, but feedback for real-time navigation is limited. Haptic display…
DiagnosticA Vision-Language-Action Model for Adaptive Ultrasound-Guided Needle Insertion and Needle Tracking
Ultrasound (US)-guided needle insertion is a critical yet challenging procedure due to dynamic imaging conditions and difficulties in needle visualization. Many methods have been proposed for automated needle insertion, …
Medical needle tip tracking based on Optical Imaging and AI
Deep needle insertion to a target often poses a huge challenge, requiring a combination of specialized skills, assistive technology, and extensive training. One of the frequently encountered medical scenarios demanding s…
Anatomy