Deep Learning Adapted Acceleration for Limited-view Photoacoustic Computed Tomography
Photoacoustic imaging (PAI) is a non-invasive imaging modality that detects the ultrasound signal generated from tissue with light excitation. Photoacoustic computed tomography (PACT) uses unfocused large-area light to illuminate the target with ultrasound transducer array for PA signal detection. Limited-view issue could cause a low-quality image in PACT due to the limitation of geometric condition. The model-based method is used to resolve this problem, which contains different regularization. To adapt fast and high-quality reconstruction of limited-view PA data, in this paper, a model-based method that combines the mathematical variational model with deep learning is proposed to speed up and regularize the unrolled procedure of reconstruction. A deep neural network is designed to adapt the step of the gradient updated term of data consistency in the gradient descent procedure, which can obtain a high-quality PA image only with a few iterations. Note that all parameters and priors are automatically learned during the offline training stage. In experiments, we show that this method outperforms the other methods with half-view (180 degrees) simulation and real data. The comparison of different model-based methods show that our proposed scheme has superior performances (over 0.05 for SSIM) with same iteration (3 times) steps. Furthermore, an unseen data is used to validate the generalization of different methods. Finally, we find that our method obtains superior results (0.94 value of SSIM for in vivo) with a high robustness and accelerated reconstruction.
Code (0)
등록된 구현이 없습니다.
Tasks
Deep LearningSSIMMethods 이 논문이 사용한 방법론
Similar Papers 제목 키워드 기반
Limited-View Photoacoustic Imaging Reconstruction Via High-quality Self-supervised Neural Representation
In practical applications within the human body, it is often challenging to fully encompass the target tissue or organ, necessitating the use of limited-view arrays, which can lead to the loss of crucial information. Add…
Image ReconstructionA Jointed Feature Fusion Framework for Photoacoustic Reconstruction
Photoacoustic (PA) computed tomography (PACT) reconstructs the initial pressure distribution from raw PA signals. The standard reconstruction of medical image could cause the artifacts due to interferences or ill-posed s…
Image ReconstructionPositionGPAIR: Gaussian-Kernel-Based Ultrafast 3D Photoacoustic Iterative Reconstruction
Although the iterative reconstruction (IR) algorithm can substantially correct reconstruction artifacts in photoacoustic (PA) computed tomography (PACT), it suffers from long reconstruction times, especially for large-sc…
Image ReconstructionSuper-temporal-resolution Photoacoustic Imaging with Dynamic Reconstruction through Implicit Neural Representation in Sparse-view
Dynamic Photoacoustic Computed Tomography (PACT) is an important imaging technique for monitoring physiological processes, capable of providing high-contrast images of optical absorption at much greater depths than tradi…
Dynamic ReconstructionImage ReconstructionModel based learning for accelerated, limited-view 3D photoacoustic tomography
Recent advances in deep learning for tomographic reconstructions have shown great potential to create accurate and high quality images with a considerable speed-up. In this work we present a deep neural network that is s…
Tomographic Reconstructions