Design and Analysis of a Sample-and-Hold CMOS Electrochemical Sensor for Aptamer-based Therapeutic Drug Monitoring
In this paper, we present the design and the analysis of an electrochemical circuit for measuring the concentrations of therapeutic drugs using structure-switching aptamers. Aptamers are single-stranded nucleic acids, whose sequence is selected to exhibit high affinity and specificity toward a molecular target, and change its conformation upon binding. This property, when coupled with a redox reporter and electrochemical detection, enables reagent-free biosensing with a sub-minute temporal resolution for in vivo therapeutic drug monitoring. Specifically, we design a chronoamperometry-based electrochemical circuit that measures the direct changes in the electron transfer (ET) kinetics of a methylene blue reporter conjugated at the distal-end of the aptamer. To overcome the high-frequency noise amplification issue when interfacing with a large-size (> 0.25 mm2) implantable electrode, we present a sample-and-hold (S/H) circuit technique in which the desired electrode potentials are held onto noiseless capacitors during the recording of the redox currents. This allows disconnecting the feedback amplifiers to avoid its noise injection while reducing the total power consumption. A prototype circuit implemented in 65-nm CMOS demonstrates a cell-capacitance-insensitive input-referred noise (IRN) current of 15.2 pArms at a 2.5-kHz filtering bandwidth. Tested in human whole blood samples, changes in the ET kinetics from the redox-labeled aminoglycoside aptamers at different kanamycin concentrations are measured from the recorded current waveforms. By employing principal component analysis (PCA) to compensate for the sampling errors, a detection limit (SNR = 1) of 3.1 uM under 1-sec acquisition is achieved at 0.22-mW power consumption.
Code (0)
등록된 구현이 없습니다.
Tasks
SpecificitySimilar Papers 제목 키워드 기반
Programmable Transimpedance Amplifier with Integrated Bandgap Reference for Glucose Concentration Measurement
For glucose electrochemical sensors, a comprehensive electronics interface is designed and constructed in 0.18 um, CMOS process technology, and 1.5 V supply voltage. This interface includes a programmable readout amplifi…
Optimized Cryo-CMOS Technology with VTH<0.2V and Ion>1.2mA/um for High-Peformance Computing
We report the design-technology co-optimization (DTCO) scheme to develop a 28-nm cryogenic CMOS (Cryo-CMOS) technology for high-performance computing (HPC). The precise adjustment of halo implants manages to compensate t…
Design and Comparative Analysis of a Two-Stage Ultra-Low-Power Subthreshold Operational Amplifier in 180nm, 90nm, and 45nm technology
In this paper, a two-stage ultra-low-power operational amplifier is designed, and a comparative analysis of the proposed subthreshold complementary amplifier is presented between 180nm, 90nm, and 45nm CMOS technology. Th…
Accelerating and enhancing thermodynamic simulations of electrochemical interfaces
Electrochemical interfaces are crucial in catalysis, energy storage, and corrosion, where their stability and reactivity depend on complex interactions between the electrode, adsorbates, and electrolyte. Predicting stabl…
Sensor technologies in cancer research for new directions in diagnosis and treatment: and exploratory analysis
The goal of this study is an exploratory analysis concerning main sensor technologies applied in cancer research to detect new directions in diagnosis and treatments. The study focused on types of cancer having a high in…