Distributed optimization for nonrigid nano-tomography
Resolution level and reconstruction quality in nano-computed tomography (nano-CT) are in part limited by the stability of microscopes, because the magnitude of mechanical vibrations during scanning becomes comparable to the imaging resolution, and the ability of the samples to resist beam damage during data acquisition. In such cases, there is no incentive in recovering the sample state at different time steps like in time-resolved reconstruction methods, but instead the goal is to retrieve a single reconstruction at the highest possible spatial resolution and without any imaging artifacts. Here we propose a joint solver for imaging samples at the nanoscale with projection alignment, unwarping and regularization. Projection data consistency is regulated by dense optical flow estimated by Farneback's algorithm, leading to sharp sample reconstructions with less artifacts. Synthetic data tests show robustness of the method to Poisson and low-frequency background noise. Applicability of the method is demonstrated on two large-scale nano-imaging experimental data sets.
Code (1)
Tasks
Distributed OptimizationOptical Flow EstimationSimilar Papers 제목 키워드 기반
X-ray nano-holotomography reconstruction with simultaneous probe retrieval
In conventional tomographic reconstruction, the pre-processing step includes flat-field correction, where each sample projection on the detector is divided by a reference image taken without the sample. When using cohere…
3D ReconstructionRetrievalRobust Nonrigid Registration by Convex Optimization
We present an approach to nonrigid registration of 3D surfaces. We cast isometric embedding as MRF optimization and apply efficient global optimization algorithms based on linear programming relaxations. The Markov rando…
global-optimizationNear-Isotropic Sub-Ångstrom 3D Resolution Phase Contrast Imaging Achieved by End-to-End Ptychographic Electron Tomography
Three-dimensional atomic resolution imaging using transmission electron microscopes is a unique capability that requires challenging experiments. Linear electron tomography methods are limited by the missing wedge effect…
Electron TomographyA complete data processing workflow for CryoET and subtomogram averaging
Electron cryotomography (CryoET) is currently the only method capable of visualizing cells in 3D at nanometer resolutions. While modern instruments produce massive amounts of tomography data containing extremely rich str…
Cryogenic Electron TomographyGradient-Informed Bayesian and Interior Point Optimization for Efficient Inverse Design in Nanophotonics
Inverse design, particularly geometric shape optimization, provides a systematic approach for developing high-performance nanophotonic devices. While numerous optimization algorithms exist, previous global approaches exh…