DMCVR: Morphology-Guided Diffusion Model for 3D Cardiac Volume Reconstruction

2023-08-18 · Xiaoxiao He, Chaowei Tan, Ligong Han, Bo Liu, Leon Axel, Kang Li, Dimitris N. Metaxas

Accurate 3D cardiac reconstruction from cine magnetic resonance imaging (cMRI) is crucial for improved cardiovascular disease diagnosis and understanding of the heart's motion. However, current cardiac MRI-based reconstruction technology used in clinical settings is 2D with limited through-plane resolution, resulting in low-quality reconstructed cardiac volumes. To better reconstruct 3D cardiac volumes from sparse 2D image stacks, we propose a morphology-guided diffusion model for 3D cardiac volume reconstruction, DMCVR, that synthesizes high-resolution 2D images and corresponding 3D reconstructed volumes. Our method outperforms previous approaches by conditioning the cardiac morphology on the generative model, eliminating the time-consuming iterative optimization process of the latent code, and improving generation quality. The learned latent spaces provide global semantics, local cardiac morphology and details of each 2D cMRI slice with highly interpretable value to reconstruct 3D cardiac shape. Our experiments show that DMCVR is highly effective in several aspects, such as 2D generation and 3D reconstruction performance. With DMCVR, we can produce high-resolution 3D cardiac MRI reconstructions, surpassing current techniques. Our proposed framework has great potential for improving the accuracy of cardiac disease diagnosis and treatment planning. Code can be accessed at https://github.com/hexiaoxiao-cs/DMCVR.

📄 PDF Abstract BibTeX arXiv:2308.09223

Code (1)

hexiaoxiao-cs/dmcvr 공식 구현 pytorch

Tasks

3D Reconstruction

Methods 이 논문이 사용한 방법론

Diffusion Diffusion models generate samples by gradually removing noise from a signal, and their training objective can be expressed as a reweighted variational lower-bound…

Similar Papers 제목 키워드 기반

Grouping Similar Seismocardiographic Signals Using Respiratory Information

2017-11-29

Seismocardiography (SCG) offers a potential non-invasive method for cardiac monitoring. Quantification of the effects of different physiological conditions on SCG can lead to enhanced understanding of SCG genesis, and ma…

Epicardium Prompt-guided Real-time Cardiac Ultrasound Frame-to-volume Registration

2024-06-20 · Long Lei, Jun Zhou, Jialun Pei, Baoliang Zhao 외

A comprehensive guidance view for cardiac interventional surgery can be provided by the real-time fusion of the intraoperative 2D images and preoperative 3D volume based on the ultrasound frame-to-volume registration. Ho…

CardioDiT: Latent Diffusion Transformers for 4D Cardiac MRI Synthesis

2026-03-26 · Marvin Seyfarth, Sarah Kaye Müller, Arman Ghanaat, Isabelle Ayx 외 arxiv

Latent diffusion models (LDMs) have recently achieved strong performance in 3D medical image synthesis. However, modalities like cine cardiac MRI (CMR), representing a temporally synchronized 3D volume across the cardiac…

PG-LRF: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation

2026-05-09 · Xiaoda Wang, Minxiao Wang, Kaiqiao Han, Defu Cao 외 arxiv

Electrocardiography (ECG) is the clinical standard for cardiac assessment but requires dedicated hardware that does not scale to daily-life monitoring. Photoplethysmography (PPG) is ubiquitous in wearables but lacks ECG-…

High-Resolution Reference Image Assisted Volumetric Super-Resolution of Cardiac Diffusion Weighted Imaging

2023-10-31 · Yinzhe Wu, Jiahao Huang, Fanwen Wang, Pedro Ferreira 외

Diffusion Tensor Cardiac Magnetic Resonance (DT-CMR) is the only in vivo method to non-invasively examine the microstructure of the human heart. Current research in DT-CMR aims to improve the understanding of how the car…

Super-Resolution