paper-with-me

홈 › Papers

Dynamic Shimming in the Cervical Spinal Cord for Multi-Echo Gradient-Echo Imaging at 3 T

2021-07-21 · E. Alonso-Ortiz, D. Papp, A. D'Astous, J. Cohen-Adad

Obtaining high quality images of the spinal cord with MRI is difficult, partly due to the fact that the spinal cord is surrounded by a number of structures that have differing magnetic susceptibility. This causes inhomogeneities in the magnetic field, which in turn lead to image artifacts. In order to address this issue, linear compensation gradients can be employed. The latter can be generated using an MRI scanner's first order gradient coils and adjusted on a per-slice basis, in order to correct for through-plane ("z") magnetic field gradients. This approach is referred to as z-shimming. The aim of this study is two-fold. The first aim was to replicate aspects of a previous study wherein z-shimming was found to improve image quality in T2*-weighted echo-planar imaging. Our second aim was to improve upon the z-shimming approach by including in-plane compensation gradients and adjusting the compensation gradients during the image acquisition process so that they take into account respiration-induced magnetic field variations. We refer to this novel approach as realtime dynamic shimming. Measurements performed in a group of 12 healthy volunteers at 3 T show improved signal homogeneity along the spinal cord when using z-shimming. Signal homogeneity may be further improved by including realtime compensation for respiration-induced field gradients and by also doing this for gradients along the in-plane axes.

📄 PDF Abstract BibTeX arXiv:2107.10331

Code (1)

neuropoly/realtime-dynamic-shimming 공식 구현

Similar Papers 제목 키워드 기반

Reproducibility and Evolution of Diffusion MRI Measurements within the Cervical Spinal Cord in Multiple Sclerosis

2021-08-08 · Haykel Snoussi, Emmanuel Caruyer, Benoit Combes, Olivier Commowick 외

In Multiple Sclerosis (MS), there is a large discrepancy between the clinical observations and how the pathology is exhibited on brain images, this is known as the clinical-radiological paradox (CRP). One of the hypothes…

Diffusion MRI

Toward Deep Learning-based Segmentation and Quantitative Analysis of Cervical Spinal Cord Magnetic Resonance Images

2024-09-28 · Maryam Tavakol Elahi

This research proposal discusses two challenges in the field of medical image analysis: the multi-parametric investigation on microstructural and macrostructural characteristics of the cervical spinal cord and deep learn…

Deep LearningImage SegmentationMedical Image AnalysisMedical Image Segmentation+1

Effectiveness of regional diffusion MRI measures in distinguishing multiple sclerosis abnormalities within the cervical spinal cord

2021-08-09 · Haykel Snoussi, Julien Cohen-Adad, Benoit Combes, Elise Bannier 외

Multiple sclerosis is an inflammatory disorder of the central nervous system. Quantitative MRI has huge potential to provide intrinsic and normative values of tissue properties useful for diagnosis, prognosis and ultimat…

Diffusion MRIPrognosisQuantitative MRI

Pathology-Guided AI System for Accurate Segmentation and Diagnosis of Cervical Spondylosis

2025-03-08 · Qi Zhang, Xiuyuan Chen, Ziyi He, Lianming Wu 외

Cervical spondylosis, a complex and prevalent condition, demands precise and efficient diagnostic techniques for accurate assessment. While MRI offers detailed visualization of cervical spine anatomy, manual interpretati…

AnatomyDiagnosticSegmentation

Multiclass Spinal Cord Tumor Segmentation on MRI with Deep Learning

2020-12-23 · Andreanne Lemay, Charley Gros, Zhizheng Zhuo, Jie Zhang 외

Spinal cord tumors lead to neurological morbidity and mortality. Being able to obtain morphometric quantification (size, location, growth rate) of the tumor, edema, and cavity can result in improved monitoring and treatm…

Deep LearningSegmentationTumor Segmentation