paper-with-me

Papers

FrequencyCT: Frequency Domain Self-supervised Low-dose CT Denoising

2026-05-11 · Guoquan Wei, Liu Shi, Chong Chen, Qiegen Liu arxiv

Despite extensive research on computed tomography (CT) denoising, few studies exploit projection-domain data characteristics to mitigate noise correlation. To bridge this gap, this work proposes FrequencyCT, the first zero-shot self-supervised method for pseudo-sample generation in the frequency domain for low-dose CT denoising. Specifically, by exploiting the distinct frequency-domain distributions of noise and true signal, a regional low-frequency anchoring technique is proposed. Applying phase-preserving noise and mask perturbations to the high-frequency region generates pseudo-samples for self-supervision. Driven by the exponential correlation between noise variance of noisy projections and the underlying true signal, consistent data truncation is applied to the generated samples to stabilize optimization gradients. Evaluation results on multiple public and real datasets confirm the clinical application potential of this research, which provides an innovative perspective for the field of denoising. The code is available at: https://github.com/yqx7150/FrequencyCT.

📄 PDF Abstract BibTeX arXiv:2605.10583

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

WIA-LD2ND: Wavelet-based Image Alignment for Self-supervised Low-Dose CT Denoising

2024-03-18 · Haoyu Zhao, Yuliang Gu, Zhou Zhao, Bo Du 외

In clinical examinations and diagnoses, low-dose computed tomography (LDCT) is crucial for minimizing health risks compared with normal-dose computed tomography (NDCT). However, reducing the radiation dose compromises th…

DenoisingImage Denoising

Window-Level is a Strong Denoising Surrogate

2021-05-15 · Ayaan Haque, Adam Wang, Abdullah-Al-Zubaer Imran

CT image quality is heavily reliant on radiation dose, which causes a trade-off between radiation dose and image quality that affects the subsequent image-based diagnostic performance. However, high radiation can be harm…

DenoisingDiagnosticImage DenoisingSelf-Supervised Learning

Self-Supervised Training For Low Dose CT Reconstruction

2020-10-25 · Mehmet Ozan Unal, Metin Ertas, Isa Yildirim

Ionizing radiation has been the biggest concern in CT imaging. To reduce the dose level without compromising the image quality, low-dose CT reconstruction has been offered with the availability of compressed sensing base…

compressed sensingCT Reconstruction

Extendable Generalization Self-Supervised Diffusion for Low-Dose CT Reconstruction

2025-09-28 · Guoquan Wei, Liu Shi, Zekun Zhou, Mohan Li 외 arxiv

Current methods based on deep learning for self-supervised low-dose CT (LDCT) reconstruction, while reducing the dependence on paired data, face the problem of significantly decreased generalization when training with si…

Knowledge Distillation

Low-dose CT Enhancement Network with a Perceptual Loss Function in the Spatial Frequency and Image Domains

2020-05-26 · MIDL 2019 7

We propose a dual-domain cascade of U-nets (i.e. a "W-net") operating in both the spatial frequency and image domains to enhance low-dose CT (LDCT) images without the need for proprietary x-ray projection data. The centr…

Diagnostic