Geometric Artifact Correction for Symmetric Multi-Linear Trajectory CT: Theory, Method, and Generalization

2024-08-27 · Zhisheng Wang, Yanxu Sun, Shangyu Li, Legeng Lin, Shunli Wang, Junning Cui

For extending CT field-of-view to perform non-destructive testing, the Symmetric Multi-Linear trajectory Computed Tomography (SMLCT) has been developed as a successful example of non-standard CT scanning modes. However, inevitable geometric errors can cause severe artifacts in the reconstructed images. The existing calibration method for SMLCT is both crude and inefficient. It involves reconstructing hundreds of images by exhaustively substituting each potential error, and then manually identifying the images with the fewest geometric artifacts to estimate the final geometric errors for calibration. In this paper, we comprehensively and efficiently address the challenging geometric artifacts in SMLCT, , and the corresponding works mainly involve theory, method, and generalization. In particular, after identifying sensitive parameters and conducting some theory analysis of geometric artifacts, we summarize several key properties between sensitive geometric parameters and artifact characteristics. Then, we further construct mathematical relationships that relate sensitive geometric errors to the pixel offsets of reconstruction images with artifact characteristics. To accurately extract pixel bias, we innovatively adapt the Generalized Cross-Correlation with Phase Transform (GCC-PHAT) algorithm, commonly used in sound processing, for our image registration task for each paired symmetric LCT. This adaptation leads to the design of a highly efficient rigid translation registration method. Simulation and physical experiments have validated the excellent performance of this work. Additionally, our results demonstrate significant generalization to common rotated CT and a variant of SMLCT.

📄 PDF Abstract BibTeX arXiv:2408.15069

Code (0)

등록된 구현이 없습니다.

Tasks

Image Registration

Similar Papers 제목 키워드 기반

AS-Mamba: Asymmetric Self-Guided Mamba Decoupled Iterative Network for Metal Artifact Reduction

2026-02-06 · Bowen Ning, Zekun Zhou, Xinyi Zhong, Zhongzhen Wang 외 arxiv

Metal artifact significantly degrades Computed Tomography (CT) image quality, impeding accurate clinical diagnosis. However, existing deep learning approaches, such as CNN and Transformer, often fail to explicitly captur…

GDCNet: Calibrationless geometric distortion correction of echo planar imaging data using deep learning

2024-02-29 · Marina Manso Jimeno, Keren Bachi, George Gardner, Yasmin L. Hurd 외

Functional magnetic resonance imaging techniques benefit from echo-planar imaging's fast image acquisition but are susceptible to inhomogeneities in the main magnetic field, resulting in geometric distortion and signal l…

distortion correction

Texture Mapping for 3D Reconstruction With RGB-D Sensor

2018-06-01 · CVPR 2018 6 · Yanping Fu, Qingan Yan, Long Yang, Jie Liao 외

Acquiring realistic texture details for 3D models is important in 3D reconstruction. However, the existence of geometric errors, caused by noisy RGB-D sensor data, always makes the color images cannot be accurately align…

3D Reconstruction

DocTr: Document Image Transformer for Geometric Unwarping and Illumination Correction

2021-10-25 · Hao Feng, Yuechen Wang, Wengang Zhou, Jiajun Deng 외

In this work, we propose a new framework, called Document Image Transformer (DocTr), to address the issue of geometry and illumination distortion of the document images. Specifically, DocTr consists of a geometric unwarp…

Optical Character Recognition (OCR)

Multi-Material Blind Beam Hardening Correction Based on Non-Linearity Adjustment of Projections

2022-03-09 · Ammar Alsaffar, Kaicong Sun, Sven Simon

Beam hardening (BH) is one of the major artifacts that severely reduces the quality of Computed Tomography (CT) imaging. In a polychromatic X-ray beam, since low-energy photons are more preferentially absorbed, the atten…

Computed Tomography (CT)