Hidden Degradation Costs in Energy-Cost-Only HEMS Optimisation: Study on Battery and PV Sensitivity
Residential battery energy storage systems (BESS) are increasingly deployed alongside photovoltaic (PV) generation to reduce household energy costs under volatile time-of-use (TOU) tariffs. Model predictive control (MPC) is a widely adopted optimisation strategy for home energy management systems (HEMS), typically formulated to minimise net energy cost, subject to physical and operational constraints. However, battery degradation is rarely embedded in the optimisation objective, meaning its cost is unquantified and aggressive; high-cycle-count strategies could incur significant losses once deployed to physical systems. This paper presents a receding-horizon mixed-integer linear programming (MILP) baseline for a UK residential HEMS, using demand data from the REFIT dataset. A 3 by 3 sensitivity study is conducted across three battery sizes and three PV array sizes, with post-hoc degradation cost estimated using the Naumann stress model and rainflow cycle counting. Results show that degradation remains constant for each battery size and can exceed energy cost savings by up to 1,060 %. These results demonstrate that energy-cost-only optimisation systematically underestimates the true system cost, motivating a degradation-aware control formulation.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Enhanced Battery Degradation-Aware Scheduling for Distribution Network with Electric Vehicle Load
Batteries play a key role in today's power grid. In this paper, we investigate the impact of battery degradation on the distribution network. We formulate a multi-objective framework for optimizing battery scheduling wit…
SchedulingEnhancing Optimal Microgrid Planning with Adaptive BESS Degradation Costs and PV Asset Management: An Iterative Post-Optimization Correction Framework
The transition to renewable energy has positioned photovoltaic (PV) systems and battery energy storage systems (BESS) as essential assets in microgrids, particularly for remote installations. However, traditional plannin…
Asset ManagementSchedulingAging-aware Energy Management for Residential Multi-Carrier Energy Systems
In the context of building electrification, the operation of distributed energy resources integrating multiple energy carriers (electricity, heat, mobility) poses a significant challenge due to the nonlinear device dynam…
energy managementManagementDegradation-Aware Microgrid Optimal Planning: Integrating Dynamic Energy Efficiencies and Second-Life Battery Potential
Traditional microgrid planning often overlooks PV and BESS degradation or relies on complex, downscaled models, leading to unreliable, costly and suboptimal investment decisions. This paper presents a degradation-based i…
Asset ManagementEconomic Optimal Power Management of Second-Life Battery Energy Storage Systems
Second-life battery energy storage systems (SL-BESS) are an economical means of long-duration grid energy storage. They utilize retired battery packs from electric vehicles to store and provide electrical energy at the u…
Management