Improving Photoplethysmographic Measurements under Motion Artifacts using Artificial Neural Network for Personal Healthcare
Photoplethysmographic (PPG) measurements are susceptible to motion artifacts (MA) due to movement of the peripheral body parts. In this paper, we present a new approach to identify the MA corrupted PPG beats and then rectify the beat morphology using artificial neural network (ANN). Initially, beat quality assessment was done to identify the clean PPG beats by a pre-trained feedback ANN to generate a reference beat template for each person. The PPG data was decomposed using principal component analysis (PCA) and reconstructed using fixed energy retention. A weight coefficient was assigned for each PPG samples in such a way that when they are multiplied , the modified beat morphology matches the reference template. A particle swarm optimization (PSO) based technique was utilized to select the best weight weight vector coefficients to tune another feedback ANN, fed with a set of significant features generated by an auto encoder from PCA reconstructed data. For real time implementation, this pre-trained ANN was operated in feed-forward mode to directly generate the weight vectors for any subsequent measurements of PPG. The method was validated with PPG data collected from 55 human subjects. An average RMSE of 0.28 and SNR improvement of 14.54 dB was obtained, with an average improvement of 36% and 47% measurement accuracy on crest time and systolic to diastolic peak height ratio respectively. With IEEE Signal Processing Cup 2015 Challenge database, Pearson's correlation coefficient between PPG estimated and ECG derived heart rate was 0.990. The proposed method can be useful for personal health monitoring applications.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
SPECMAR: Fast Heart Rate Estimation from PPG Signal using a Modified Spectral Subtraction Scheme with Composite Motion Artifacts Reference Generation
The task of heart rate estimation using photoplethysmographic (PPG) signal is challenging due to the presence of various motion artifacts in the recorded signals. In this paper, a fast algorithm for heart rate estimation…
Heart rate estimationSupervised Heart Rate Tracking using Wrist-Type Photoplethysmographic (PPG) Signals during Physical Exercise without Simultaneous Acceleration Signals
PPG based heart rate (HR) monitoring has recently attracted much attention with the advent of wearable devices such as smart watches and smart bands. However, due to severe motion artifacts (MA) caused by wristband stumb…
Phase space reconstruction from a biological time series. A PhotoPlethysmoGraphic signal a case study
In the analysis of biological time series, the state space comprises a framework for the study of systems with presumably deterministic properties. However, a physiological experiment typically captures an observable, or…
Time SeriesTime Series AnalysisA spectral-spatial fusion model for robust blood pulse waveform extraction in photoplethysmographic imaging
Photoplethysmographic imaging is a camera-based solution for non-contact cardiovascular monitoring from a distance. This technology enables monitoring in situations where contact-based devices may be problematic or infea…
Non-contact transmittance photoplethysmographic imaging (PPGI) for long-distance cardiovascular monitoring
Photoplethysmography (PPG) devices are widely used for monitoring cardiovascular function. However, these devices require skin contact, which restrict their use to at-rest short-term monitoring using single-point measure…
Photoplethysmography (PPG)