Inter-Beat Interval Estimation with Tiramisu Model: A Novel Approach with Reduced Error
Inter-beat interval (IBI) measurement enables estimation of heart-rate variability (HRV) which, in turns, can provide early indication of potential cardiovascular diseases. However, extracting IBIs from noisy signals is challenging since the morphology of the signal is distorted in the presence of the noise. Electrocardiogram (ECG) of a person in heavy motion is highly corrupted with noise, known as motion-artifact, and IBI extracted from it is inaccurate. As a part of remote health monitoring and wearable system development, denoising ECG signals and estimating IBIs correctly from them have become an emerging topic among signal-processing researchers. Apart from conventional methods, deep-learning techniques have been successfully used in signal denoising recently, and diagnosis process has become easier, leading to accuracy levels that were previously unachievable. We propose a deep-learning approach leveraging tiramisu autoencoder model to suppress motion-artifact noise and make the R-peaks of the ECG signal prominent even in the presence of high-intensity motion. After denoising, IBIs are estimated more accurately expediting diagnosis tasks. Results illustrate that our method enables IBI estimation from noisy ECG signals with SNR up to -30dB with average root mean square error (RMSE) of 13 milliseconds for estimated IBIs. At this noise level, our error percentage remains below 8% and outperforms other state of the art techniques.
Code (1)
Tasks
DenoisingHeart Rate VariabilitySimilar Papers 제목 키워드 기반
Signal-to-noise ratio is more important than sampling rate in beat-to-beat interval estimation from optical sensors
Photoplethysmographic Imaging (PPGI) allows the determination of pulse rate variability from sequential beat-to-beat intervals (BBI) and pulse wave velocity from spatially resolved recorded pulse waves. In either case, s…
Accurate Radar-Based Heartbeat Measurement Using Higher Harmonic Components
This study proposes a radar-based heartbeat measurement method that uses the absolute value of the second derivative of the complex radar signal, rather than its phase, and the variational mode extraction method, which i…
Complex Number Assignment in the Topology Method for Heartbeat Interval Estimation Using Millimeter-Wave Radar
The topology method is an algorithm for accurate estimation of instantaneous heartbeat intervals using millimeter-wave radar signals. In this model, feature points are extracted from the skin displacement waveforms gener…
Tiramisu: A Polyhedral Compiler for Expressing Fast and Portable Code
This paper introduces Tiramisu, a polyhedral framework designed to generate high performance code for multiple platforms including multicores, GPUs, and distributed machines. Tiramisu introduces a scheduling language wit…
SchedulingGreedy-optimized Approach for Interbeat Interval and Heart Rate Variability Daily Monitoring using Wearable PPG
Continuous monitoring of heart rate variability (HRV) provides insights in cardiovascular health. Wearable Photoplethysmography (PPG) assures convenient measurement of HRV. PPG, however, is susceptible to motion artifact…
Heart Rate VariabilityPhotoplethysmography (PPG)