Modelling of AC/DC Interactions of Converter-Interfaced Resources for Harmonic Power-Flow Studies in Microgrids
Power distribution systems experience a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). As acknowledged by recent literature, the interaction of individual CIDER components and different CIDERs through the grid can lead to undesirable amplification of harmonic frequencies and, ultimately, compromise the distribution system stability. In this context, the interaction of the DC and AC sides of CIDERs has been shown to have a significant impact. In order to analyze and support the mitigation of such phenomena, the authors of this paper recently proposed a Harmonic Power-Flow (HPF) framework for polyphase grids with a high share of CIDERs. The framework considers the coupling between harmonics, but ignores the DC-side response of the CIDERs. Modelling the DC side and AC/DC converter introduces a nonlinearity into the CIDER model that needs to be approximated for the numerical solution of the HPF. This paper extends the CIDER model and HPF framework to address this aspect, whose inclusion is non-trivial. The extended HPF method is applied to a modified version of the CIGRE low-voltage benchmark microgrid. The results are compared to (i) time-domain simulations with Simulink, (ii) the predecessor of the extended HPF which neglects the DC side, and (iii) a classical decoupled HPF.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Harmonic Power-Flow Study of Polyphase Grids with Converter-Interfaced Distributed Energy Resources, Part I: Modelling Framework and Algorithm
Power distribution systems are experiencing a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). This complicates the analysis and mitigation of harmonics, whose creation and propagati…
Computational EfficiencyHarmonic Stability Analysis of Microgrids with Converter-Interfaced Distributed Energy Resources, Part I: Modelling and Theoretical Foundations
This paper proposes a method for the Harmonic Stability Assessment (HSA) of power systems with a high share of Converter-Interfaced Distributed Energy Resources (CIDERs). To this end, the Harmonic State-Space (HSS) model…
Harmonic Stability Analysis of Microgrids with Converter-Interfaced Distributed Energy Resources, Part II: Case Studies
In Part I of this paper a method for the Harmonic Stability Assessment (HSA) of power systems with a high share of Converter-Interfaced Distributed Energy Resources (CIDERs) was proposed. Specifically, the Harmonic State…
Harmonic Power-Flow Study of Hybrid AC/DC Grids with Converter-Interfaced Distributed Energy Resources
As the share of Converter-Interfaced Distributed Energy Resources (CIDERs) in power distribution systems increases, hybrid AC/DC distribution systems are drawing more interest. Indeed, CIDERs usually rely on DC power and…
Ensuring Solution Uniqueness in Fixed-Point-Based Harmonic Power Flow Analysis with Converter-Interfaced Resources: Ex-post Conditions
Recently, the authors of this paper proposed a method for the Harmonic Power-Flow (HPF) calculus in polyphase grids with widespread deployment of Converter-Interfaced Distributed Energy Resources (CIDERs). The HPF proble…