The present work addresses the experimental identification of amplitude-dependent modal parameters (modal frequency, damping ratio, Fourier coefficients of periodic modal oscillation). Phase-resonant testing has emerged as an important method for this task, as it substantially reduces the amount of data required for the identification compared to conventional frequency-response testing at different excitation/response levels. In the case of shaker-stinger excitation, the applied excitation force is commonly measured in order to quantify the amplitude-dependent modal damping ratio from the phase-resonant test data. In the case of base excitation, however, the applied excitation force is challenging or impossible to measure. In this work we develop an original method for damping quantification from phase-resonant tests. It relies solely on response measurement; it avoids the need to resort to force measurement. The key idea is to estimate the power provided by the distributed inertia force imposed by the base motion. We develop both a model-free and a model-based variant of the method. We validate the developed method first in virtual experiments of a friction-damped and a geometrically nonlinear system, and then in a physical experiment involving a thin beam clamped at both ends via bolted joints. We conclude that the method is highly robust and provides high accuracy already for a reasonable number of sensors.
Code (0)
등록된 구현이 없습니다.
Tasks
FrictionMethods 이 논문이 사용한 방법론
Similar Papers 제목 키워드 기반
Non-Minimum-Phase Resonant Controller for Active Damping Control: Application to Piezo-Actuated Nanopositioning System
Nanopositioning systems frequently encounter limitations in control bandwidth due to their lightly damped resonance behavior. This paper presents a novel Non-Minimum-Phase Resonant Controller (NRC) aimed at active dampin…
Nonlinearity Characteristic of High Impedance Fault at Resonant Distribution Networks: Theoretical Basis to Identify the Faulty Feeder
Feeder identification is indispensable for distribution networks to locate faults at a specific feeder, especially when measuring de-vices are insufficient for precise locations. For the high imped-ance fault (HIF), the …
DiversityFast and Efficient Estimation of Resonant Modes: A Case Study of Mechanical Drivelines
This work presents the development of an online parameter estimation algorithm for the identification of resonating modes in a linear system of arbitrary order. The method employs a short-time Fourier transform of the in…
parameter estimationCavity-Enhanced Collective Quantum Processing with Polarization-Encoded Qubits
We introduce a cavity-enhanced optical architecture for collective quantum processing in which logical qubits are encoded in the polarization subspace of recirculating intracavity modes. The physical carrier and computat…
A Pure Integral-Type PLL with a Damping Branch to Enhance the Stability of Grid-Tied Inverter under Weak Grids
In a phase-locked loop (PLL) synchronized inverter, due to the strong nonlinear coupling between the PLL's parame-ters and the operation power angle, the equivalent damping coefficient will quickly deteriorate while the …