paper-with-me

홈 › Papers

Optimal Phasor Measurement Unit Placement Using a Honey Bee Mating Optimization (HBMO) Technique Considering Measurement Loss and Line Outages

2021-05-05 · Lorena Palmero, Ugur Saritac, Ali Dehghan Chaharabi

Phasor measurement units (PMUs) are important devices for protection, monitoring, and control of modern power systems. Unlike the supervisory control and data acquisition (SCADA) system which only measure the magnitude, PMUs can provide a set of synchronized phasor measurements with high sampling rate with the accuracy of less than one second, for better system monitoring especially during the outages. Since the PMUs are costly devices, system operator is not able to install a PMU at each bus to maximize the observability of system. To this end, determination of the number of PMUs in the system for having a 100% observability is pivotal. In this paper, honey bee mating optimization (HBMO) approach is utilized to allocate PMUs in modern power systems. Moreover, the impact of line outages, as well as measurement loses, are considered. The simulation results show the effectiveness of the proposed method on solving the PMU placement problem.

📄 PDF Abstract BibTeX arXiv:2105.02102

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

Establishment and placement of a Multi-purpose Phasor measurement unit to improve parallel state estimation in distribution Networks

2021-09-28 · Zeyad Khashroum, Ali Dehghan Chaharabi, Lorena Palmero, Keiichiro Yasukawa

Today, microgrids in distribution networks are in dire need of improvement to cope with economic challenges, human losses, and equipment placement issues. Today, there is the issue of scattered resources in distribution …

State Estimation

Optimal PMU Placement for Kalman Filtering of DAE Power System Models

2025-02-05 · Milos Katanic, Yi Guo, John Lygeros, Gabriela Hug

Optimal sensor placement is essential for minimizing costs and ensuring accurate state estimation in power systems. This paper introduces a novel method for optimal sensor placement for dynamic state estimation of power …

BenchmarkingState Estimation

Optimal Placement of Limited PMUs for Transmission Line Outage Detection and Identification

2020-05-14

Phasor Measurement Unit (PMU) technology is increasingly used for real-time monitoring applications, especially line outage detection and identification (D&I) in the power system. Current outage D&I schemes either assume…

Precision Enhancement of Distribution System State Estimation via Tri-Objective Micro Phasor Measurement Unit Deployment

2023-08-31 · Arya Abdolahi, Navid Taghizadegan Kalantari

A tri-objective optimal Micro Phasor Measurement Units ({\mu}-PMUs) Placement method is presented, with a focus on minimizing the following three parameters: i) the total number of {\mu}-PMU channels, (ii) the maximum st…

SensitivityState Estimation

A Game-Theoretic Approach for PMU Deployment Against False Data Injection Attacks

2024-04-16 · Sajjad Maleki, Subhash Lakshminarayana, E. Veronica Belmega, Carsten Maple

Phasor Measurement Units (PMUs) are used in the measurement, control and protection of power grids. However, deploying PMUs at every bus in a power system is prohibitively expensive, necessitating partial PMU placement t…