Optimal Placement of Limited PMUs for Transmission Line Outage Detection and Identification

2020-05-14

Phasor Measurement Unit (PMU) technology is increasingly used for real-time monitoring applications, especially line outage detection and identification (D&I) in the power system. Current outage D&I schemes either assume a full PMU deployment or a partial deployment with fixed PMU placement. However, the placement of the PMUs has a fundamental impact on the effectiveness of the D&I scheme. Building on a dynamic relationship between the substation voltage phase angle and active power, we formulated the optimal PMU placement problem for outage D&I as an optimization problem readily solvable by any heuristic algorithm. We tested the formulation using a genetic algorithm and simulated outages of IEEE 39 bus system. The optimal placement found produces a better D&I result of single-line outages than a randomly scattered, tree-like, and degree-based placements.

📄 PDF Abstract BibTeX arXiv:1911.02852

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

Which Neural Network to Choose for Post-Fault Localization, Dynamic State Estimation and Optimal Measurement Placement in Power Systems?

2021-04-07 · Andrei Afonin, Michael Chertkov

We consider a power transmission system monitored with Phasor Measurement Units (PMUs) placed at significant, but not all, nodes of the system. Assuming that a sufficient number of distinct single-line faults, specifical…

Fault localizationState Estimation

Optimal Phasor Measurement Unit Placement Using a Honey Bee Mating Optimization (HBMO) Technique Considering Measurement Loss and Line Outages

2021-05-05 · Lorena Palmero, Ugur Saritac, Ali Dehghan Chaharabi

Phasor measurement units (PMUs) are important devices for protection, monitoring, and control of modern power systems. Unlike the supervisory control and data acquisition (SCADA) system which only measure the magnitude, …

Multi-Objective PMU Allocation for Resilient Power System Monitoring

2020-10-15 · Hamed Haggi, Wei Sun, Junjian Qi

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-m…

A Bi-Level Stochastic Game Model for PMU Placement in Power Grid with Cybersecurity Risks

2023-01-31 · Saptarshi Ghosh, Murali Sankar Venkatraman, Shehab Ahmed, Charalambos Konstantinou

Phasor measurement units (PMUs) provide accurate and high-fidelity measurements in order to monitor the state of the power grid and support various control and planning tasks. However, PMUs have a high installation cost …

State Estimation

Revisiting the Optimal PMU Placement Problem in Multi-Machine Power Networks

2023-06-23 · Mohamad H. Kazma, Ahmad F. Taha

To provide real-time visibility of physics-based states, phasor measurement units (PMUs) are deployed throughout power networks. PMU data enable real-time grid monitoring and control -- and are essential in transitioning…