PatchCTG: Patch Cardiotocography Transformer for Antepartum Fetal Health Monitoring

2024-11-12 · M. Jaleed Khan, Manu Vatish, Gabriel Davis Jones

Antepartum Cardiotocography (CTG) is vital for fetal health monitoring, but traditional methods like the Dawes-Redman system are often limited by high inter-observer variability, leading to inconsistent interpretations and potential misdiagnoses. This paper introduces PatchCTG, a transformer-based model specifically designed for CTG analysis, employing patch-based tokenisation, instance normalisation and channel-independent processing to capture essential local and global temporal dependencies within CTG signals. PatchCTG was evaluated on the Oxford Maternity (OXMAT) dataset, comprising over 20,000 CTG traces across diverse clinical outcomes after applying the inclusion and exclusion criteria. With extensive hyperparameter optimisation, PatchCTG achieved an AUC of 77%, with specificity of 88% and sensitivity of 57% at Youden's index threshold, demonstrating adaptability to various clinical needs. Testing across varying temporal thresholds showed robust predictive performance, particularly with finetuning on data closer to delivery, achieving a sensitivity of 52% and specificity of 88% for near-delivery cases. These findings suggest the potential of PatchCTG to enhance clinical decision-making in antepartum care by providing a reliable, objective tool for fetal health assessment. The source code is available at https://github.com/jaleedkhan/PatchCTG.

📄 PDF Abstract BibTeX arXiv:2411.07796

Code (0)

등록된 구현이 없습니다.

Tasks

Decision MakingSensitivitySpecificity

Similar Papers 제목 키워드 기반

The OxMat dataset: a multimodal resource for the development of AI-driven technologies in maternal and newborn child health

2024-04-11 · M. Jaleed Khan, Ioana Duta, Beth Albert, William Cooke 외

The rapid advancement of Artificial Intelligence (AI) in healthcare presents a unique opportunity for advancements in obstetric care, particularly through the analysis of cardiotocography (CTG) for fetal monitoring. Howe…

Large language models surpass domain-specific architectures for antepartum electronic fetal monitoring analysis

2025-09-09 · Sheng Wong, Ravi Shankar, Beth Albert, Gabriel Davis Jones arxiv

Foundation models (FMs) and large language models (LLMs) have demonstrated promising generalization across diverse domains for time-series analysis, yet their potential for electronic fetal monitoring (EFM) and cardiotoc…

Computational Efficiency

A Foundation Model Approach for Fetal Stress Prediction During Labor From cardiotocography (CTG) recordings

2026-01-05 · Naomi Fridman, Berta Ben Shachar arxiv

Intrapartum cardiotocography (CTG) is widely used for fetal monitoring during labor, yet its interpretation suffers from high inter-observer variability and limited predictive accuracy. Deep learning approaches have been…

CTG-Insight: A Multi-Agent Interpretable LLM Framework for Cardiotocography Analysis and Classification

2025-07-29 · Black Sun, Die, Hu arxiv

Remote fetal monitoring technologies are becoming increasingly common. Yet, most current systems offer limited interpretability, leaving expectant parents with raw cardiotocography (CTG) data that is difficult to underst…

Simultaneous Polysomnography and Cardiotocography Reveal Temporal Correlation Between Maternal Obstructive Sleep Apnea and Fetal Hypoxia

2025-04-17 · Jingyu Wang, Donglin Xie, Jingying Ma, Yunliang Sun 외

Background: Obstructive sleep apnea syndrome (OSAS) during pregnancy is common and can negatively affect fetal outcomes. However, studies on the immediate effects of maternal hypoxia on fetal heart rate (FHR) changes are…