PyHySCO: GPU-Enabled Susceptibility Artifact Distortion Correction in Seconds
Over the past decade, reversed Gradient Polarity (RGP) methods have become a popular approach for correcting susceptibility artifacts in Echo-Planar Imaging (EPI). Although several post-processing tools for RGP are available, their implementations do not fully leverage recent hardware, algorithmic, and computational advances, leading to correction times of several minutes per image volume. To enable 3D RGP correction in seconds, we introduce PyHySCO, a user-friendly EPI distortion correction tool implemented in PyTorch that enables multi-threading and efficient use of graphics processing units (GPUs). PyHySCO uses a time-tested physical distortion model and mathematical formulation and is, therefore, reliable without training. An algorithmic improvement in PyHySCO is its novel initialization scheme that uses 1D optimal transport. PyHySCO is published under the GNU public license and can be used from the command line or its Python interface. Our extensive numerical validation using 3T and 7T data from the Human Connectome Project suggests that PyHySCO achieves accuracy comparable to that of leading RGP tools at a fraction of the cost. We also validate the new initialization scheme, compare different optimization algorithms, and test the algorithm on different hardware and arithmetic precision.
Code (1)
Tasks
distortion correctionGPUSimilar Papers 제목 키워드 기반
FD-Net: An Unsupervised Deep Forward-Distortion Model for Susceptibility Artifact Correction in EPI
Recent learning-based correction approaches in EPI estimate a displacement field, unwarp the reversed-PE image pair with the estimated field, and average the unwarped pair to yield a corrected image. Unsupervised learnin…
Computational EfficiencySusceptibility Distortion Correction of Diffusion MRI with a single Phase-Encoding Direction
Diffusion MRI (dMRI) is a valuable tool to map brain microstructure and connectivity by analyzing water molecule diffusion in tissue. However, acquiring dMRI data requires to capture multiple 3D brain volumes in a short …
Unsupervised Susceptibility Distortion Correction of EPI without Calibration Scans via Image Translation-Based Registration
Functional magnetic resonance imaging (fMRI) utilizes echo-planar imaging (EPI) to capture blood-oxygen-level-dependent (BOLD) signals with high temporal resolution. However, EPI is inherently sensitive to magnetic field…
Test-time AdaptationEddeep: Fast eddy-current distortion correction for diffusion MRI with deep learning
Modern diffusion MRI sequences commonly acquire a large number of volumes with diffusion sensitization gradients of differing strengths or directions. Such sequences rely on echo-planar imaging (EPI) to achieve reasonabl…
Diffusion MRIdistortion correctionImage RegistrationLearning to Distort: Weakly-Supervised Image Quality Transfer for Prostate DWI Correction
Single-shot echo-planar prostate diffusion-weighted imaging (DWI) is frequently complicated by geometric distortions, which impact the ability to derive reliable diagnoses from such images. Developing automated correctio…
Image Quality Assessment