paper-with-me

Papers

Real-time 3D Shape Instantiation from Single Fluoroscopy Projection for Fenestrated Stent Graft Deployment

2017-09-22 · Xiao-Yun Zhou, Jianyu Lin, Celia Riga, Guang-Zhong Yang, Su-Lin Lee

Robot-assisted deployment of fenestrated stent grafts in Fenestrated Endovascular Aortic Repair (FEVAR) requires accurate geometrical alignment. Currently, this process is guided by 2D fluoroscopy, which is uninformative and error prone. In this paper, a real-time framework is proposed to instantiate the 3D shape of a fenestrated stent graft based on only a single low-dose 2D fluoroscopic image. Firstly, the fenestrated stent graft was placed with markers. Secondly, the 3D pose of each stent segment was instantiated by the RPnP (Robust Perspective-n-Point) method. Thirdly, the 3D shape of the whole stent graft was instantiated via graft gap interpolation. Focal-Unet was proposed to segment the markers from 2D fluoroscopic images to achieve semi-automatic marker detection. The proposed framework was validated on five patient-specific 3D printed phantoms of aortic aneurysms and three stent grafts with new marker placements, showing an average distance error of 1-3mm and an average angle error of 4 degree.

📄 PDF Abstract BibTeX arXiv:1709.07689

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

Towards Automatic 3D Shape Instantiation for Deployed Stent Grafts: 2D Multiple-class and Class-imbalance Marker Segmentation with Equally-weighted Focal U-Net

2017-11-04 · Xiao-Yun Zhou Celia Riga, Su-Lin Lee, Guang-Zhong Yang

Robot-assisted Fenestrated Endovascular Aortic Repair (FEVAR) is currently navigated by 2D fluoroscopy which is insufficiently informative. Previously, a semi-automatic 3D shape instantiation method was developed to inst…

Segmentation

One-stage Shape Instantiation from a Single 2D Image to 3D Point Cloud

2019-07-24 · Xiao-Yun Zhou, Zhao-Yang Wang, Peichao Li, Jian-Qing Zheng 외

Shape instantiation which predicts the 3D shape of a dynamic target from one or more 2D images is important for real-time intra-operative navigation. Previously, a general shape instantiation framework was proposed with …

Image SegmentationImage to 3DSemantic Segmentation

Contrast-Free Autonomous Navigation of Untethered Endovascular Microrobots Using Single-Plane Fluoroscopy

2026-08-31 · Husnu Halid Alabay, Tuan-Anh Le, Ping Wang, Hakan Ceylan arxiv

Reliable three-dimensional (3D) navigation of magnetically actuated untethered microrobots remains a major barrier to clinical translation. X-ray fluoroscopy is the standard real-time imaging modality for endovascular pr…

Real-time 3D Shape Instantiation for Partially-deployed Stent Segment from a Single 2D Fluoroscopic Image in Robot-assisted Fenestrated Endovascular Aortic Repair

2019-02-28 · Jian-Qing Zheng, Xiao-Yun Zhou, Guang-Zhong Yang

In robot-assisted Fenestrated Endovascular Aortic Repair (FEVAR), accurate alignment of stent graft fenestrations or scallops with aortic branches is essential for establishing complete blood flow perfusion. Current navi…

3D Shape Reconstruction

Instantiation-Net: 3D Mesh Reconstruction from Single 2D Image for Right Ventricle

2019-09-16 · Zhao-Yang Wang, Xiao-Yun Zhou, Peichao Li, Celia Riga 외

3D shape instantiation which reconstructs the 3D shape of a target from limited 2D images or projections is an emerging technique for surgical intervention. It improves the currently less-informative and insufficient 2D …