Segmentation of Lumen and External Elastic Laminae in Intravascular Ultrasound Images using Ultrasonic Backscattering Physics Initialized Multiscale Random Walks

2019-01-21 · Debarghya China, Pabitra Mitra, Debdoot Sheet

Coronary artery disease accounts for a large number of deaths across the world and clinicians generally prefer using x-ray computed tomography or magnetic resonance imaging for localizing vascular pathologies. Interventional imaging modalities like intravascular ultrasound (IVUS) are used to adjunct diagnosis of atherosclerotic plaques in vessels, and help assess morphological state of the vessel and plaque, which play a significant role for treatment planning. Since speckle intensity in IVUS images are inherently stochastic in nature and challenge clinicians with accurate visibility of the vessel wall boundaries, it requires automation. In this paper we present a method for segmenting the lumen and external elastic laminae of the artery wall in IVUS images using random walks over a multiscale pyramid of Gaussian decomposed frames. The seeds for the random walker are initialized by supervised learning of ultrasonic backscattering and attenuation statistical mechanics from labelled training samples. We have experimentally evaluated the performance using $77$ IVUS images acquired at $40$ MHz that are available in the IVUS segmentation challenge dataset\footnote{http://www.cvc.uab.es/IVUSchallenge2011/dataset.html} to obtain a Jaccard score of $0.89 \pm 0.14$ for lumen and $0.85 \pm 0.12$ for external elastic laminae segmentation over a $10$-fold cross-validation study.

📄 PDF Abstract BibTeX arXiv:1901.06926

Code (0)

등록된 구현이 없습니다.

Similar Papers 제목 키워드 기반

CSDN: Combing Shallow and Deep Networks for Accurate Real-time Segmentation of High-definition Intravascular Ultrasound Images

2023-01-30 · Shaofeng Yuan, Feng Yang

Intravascular ultrasound (IVUS) is the preferred modality for capturing real-time and high resolution cross-sectional images of the coronary arteries, and evaluating the stenosis. Accurate and real-time segmentation of I…

Segmentation

Clinically Aligned Geometry Constraints for Robust IVUS Vessel Boundary Segmentation

2026-06-17 · Yunshu Chen, Litao Yang, Giuseppe Di Giovanni, Jordan Tan 외 arxiv

Intravascular ultrasound (IVUS) lumen and external elastic membrane (EEM) segmentation is important for quantitative coronary plaque burden assessment. Errors in lumen or EEM delineation directly propagate to plaque area…

Geo-UNet: A Geometrically Constrained Neural Framework for Clinical-Grade Lumen Segmentation in Intravascular Ultrasound

2024-08-09 · Yiming Chen, Niharika S. D'Souza, Akshith Mandepally, Patrick Henninger 외

Precisely estimating lumen boundaries in intravascular ultrasound (IVUS) is needed for sizing interventional stents to treat deep vein thrombosis (DVT). Unfortunately, current segmentation networks like the UNet lack the…

Segmentation

IVUS-Net: An Intravascular Ultrasound Segmentation Network

2018-06-10 · Ji Yang, Lin Tong, Mehdi Faraji, Anup Basu

IntraVascular UltraSound (IVUS) is one of the most effective imaging modalities that provides assistance to experts in order to diagnose and treat cardiovascular diseases. We address a central problem in IVUS image analy…

3D ReconstructionGPUSegmentation

A Deep Learning-based Method to Extract Lumen and Media-Adventitia in Intravascular Ultrasound Images

2021-02-21 · Fubao Zhu, Zhengyuan Gao, Chen Zhao, Hanlei Zhu 외

Intravascular ultrasound (IVUS) imaging allows direct visualization of the coronary vessel wall and is suitable for the assessment of atherosclerosis and the degree of stenosis. Accurate segmentation and measurements of …

Segmentation