paper-with-me

Papers

Self-supervised Fetal MRI 3D Reconstruction Based on Radiation Diffusion Generation Model

2023-10-16 · Junpeng Tan, Xin Zhang, Yao Lv, Xiangmin Xu, Gang Li

Although the use of multiple stacks can handle slice-to-volume motion correction and artifact removal problems, there are still several problems: 1) The slice-to-volume method usually uses slices as input, which cannot solve the problem of uniform intensity distribution and complementarity in regions of different fetal MRI stacks; 2) The integrity of 3D space is not considered, which adversely affects the discrimination and generation of globally consistent information in fetal MRI; 3) Fetal MRI with severe motion artifacts in the real-world cannot achieve high-quality super-resolution reconstruction. To address these issues, we propose a novel fetal brain MRI high-quality volume reconstruction method, called the Radiation Diffusion Generation Model (RDGM). It is a self-supervised generation method, which incorporates the idea of Neural Radiation Field (NeRF) based on the coordinate generation and diffusion model based on super-resolution generation. To solve regional intensity heterogeneity in different directions, we use a pre-trained transformer model for slice registration, and then, a new regionally Consistent Implicit Neural Representation (CINR) network sub-module is proposed. CINR can generate the initial volume by combining a coordinate association map of two different coordinate mapping spaces. To enhance volume global consistency and discrimination, we introduce the Volume Diffusion Super-resolution Generation (VDSG) mechanism. The global intensity discriminant generation from volume-to-volume is carried out using the idea of diffusion generation, and CINR becomes the deviation intensity generation network of the volume-to-volume diffusion model. Finally, the experimental results on real-world fetal brain MRI stacks demonstrate the state-of-the-art performance of our method.

📄 PDF Abstract BibTeX arXiv:2310.10209

Code (0)

등록된 구현이 없습니다.

Tasks

3D ReconstructionNeRFSuper-Resolution

Methods 이 논문이 사용한 방법론

Diffusion Diffusion models generate samples by gradually removing noise from a signal, and their training objective can be expressed as a reweighted variational lower-bound…

Similar Papers 제목 키워드 기반

Anatomically Constrained Tractography of the Fetal Brain

2024-03-04 · Camilo Calixto, Camilo Jaimes, Matheus D. Soldatelli, Simon K. Warfield 외

Diffusion-weighted Magnetic Resonance Imaging (dMRI) is increasingly used to study the fetal brain in utero. An important computation enabled by dMRI is streamline tractography, which has unique applications such as trac…

Segmentation

Self-Supervised Slice-to-Volume Reconstruction with Gaussian Representations for Fetal MRI

2026-01-30 · Yinsong Wang, Thomas Fletcher, Xinzhe Luo, Aine Travers Dineen 외 arxiv

Reconstructing 3D fetal MR volumes from motion-corrupted stacks of 2D slices is a crucial and challenging task. Conventional slice-to-volume reconstruction (SVR) methods are time-consuming and require multiple orthogonal…

Self-Supervised Isotropic Superresolution Fetal Brain MRI

2022-11-11 · Kay Lächler, Hélène Lajous, Michael Unser, Meritxell Bach Cuadra 외

Superresolution T2-weighted fetal-brain magnetic-resonance imaging (FBMRI) traditionally relies on the availability of several orthogonal low-resolution series of 2-dimensional thick slices (volumes). In practice, only a…

AnatomyImage Reconstruction

Unsupervised Detection of Fetal Brain Anomalies using Denoising Diffusion Models

2024-08-07 · Markus Ditlev Sjøgren Olsen, Jakob Ambsdorf, Manxi Lin, Caroline Taksøe-Vester 외

Congenital malformations of the brain are among the most common fetal abnormalities that impact fetal development. Previous anomaly detection methods on ultrasound images are based on supervised learning, rely on manual …

Anomaly DetectionDenoising

Diffusion Prior Regularized Iterative Reconstruction for Low-dose CT

2023-10-10 · Wenjun Xia, Yongyi Shi, Chuang Niu, Wenxiang Cong 외

Computed tomography (CT) involves a patient's exposure to ionizing radiation. To reduce the radiation dose, we can either lower the X-ray photon count or down-sample projection views. However, either of the ways often co…

Computed Tomography (CT)DenoisingImage Reconstruction