paper-with-me

홈 › Papers

Zero-Shot Low-dose CT Denoising via Sinogram Flicking

2025-04-10 · Yongyi Shi, Ge Wang

Many low-dose CT imaging methods rely on supervised learning, which requires a large number of paired noisy and clean images. However, obtaining paired images in clinical practice is challenging. To address this issue, zero-shot self-supervised methods train denoising networks using only the information within a single image, such as ZS-N2N. However, these methods often employ downsampling operations that degrade image resolution. Additionally, the training dataset is inherently constrained to the image itself. In this paper, we propose a zero-shot low-dose CT imaging method based on sinogram flicking, which operates within a single image but generates many copies via random conjugate ray matching. Specifically, two conjugate X-ray pencil beams measure the same path; their expected values should be identical, while their noise levels vary during measurements. By randomly swapping portions of the conjugate X-rays in the sinogram domain, we generate a large set of sinograms with consistent content but varying noise patterns. When displayed dynamically, these sinograms exhibit a flickering effect due to their identical structural content but differing noise patterns-hence the term sinogram flicking. We train the network on pairs of sinograms with the same content but different noise distributions using a lightweight model adapted from ZS-NSN. This process is repeated to obtain the final results. A simulation study demonstrates that our method outperforms state-of-the-art approaches such as ZS-N2N.

📄 PDF Abstract BibTeX arXiv:2504.07927

Code (0)

등록된 구현이 없습니다.

Tasks

Denoising

Methods 이 논문이 사용한 방법론

SET Dynamic Sparse Training method where weight mask is updated randomly periodically

Similar Papers 제목 키워드 기반

Low-Dose CT Denoising via Sinogram Inner-Structure Transformer

2022-04-07 · Liutao Yang, Zhongnian Li, Rongjun Ge, Junyong Zhao 외

Low-Dose Computed Tomography (LDCT) technique, which reduces the radiation harm to human bodies, is now attracting increasing interest in the medical imaging field. As the image quality is degraded by low dose radiation,…

DenoisingImage Reconstruction

Graph Based Sinogram Denoising for Tomographic Reconstructions

2016-03-14 · Faisal Mahmood, Nauman Shahid, Pierre Vandergheynst, Ulf Skoglund

Limited data and low dose constraints are common problems in a variety of tomographic reconstruction paradigms which lead to noisy and incomplete data. Over the past few years sinogram denoising has become an essential p…

DenoisingTomographic Reconstructions

End-to-end Triple-domain PET Enhancement: A Hybrid Denoising-and-reconstruction Framework for Reconstructing Standard-dose PET Images from Low-dose PET Sinograms

2024-12-04 · Caiwen Jiang, Mianxin Liu, Kaicong Sun, Dinggang Shen

As a sensitive functional imaging technique, positron emission tomography (PET) plays a critical role in early disease diagnosis. However, obtaining a high-quality PET image requires injecting a sufficient dose (standard…

DenoisingTriplet

TriDo-Former: A Triple-Domain Transformer for Direct PET Reconstruction from Low-Dose Sinograms

2023-08-10 · Jiaqi Cui, Pinxian Zeng, Xinyi Zeng, Peng Wang 외

To obtain high-quality positron emission tomography (PET) images while minimizing radiation exposure, various methods have been proposed for reconstructing standard-dose PET (SPET) images from low-dose PET (LPET) sinogra…

DenoisingImage ReconstructionSpectral Reconstruction

Unsupervised/Semi-supervised Deep Learning for Low-dose CT Enhancement

2018-08-08 · Mingrui Geng, Yun Deng, Qian Zhao, Qi Xie 외

Recently, deep learning(DL) methods have been proposed for the low-dose computed tomography(LdCT) enhancement, and obtain good trade-off between computational efficiency and image quality. Most of them need large number …

Computational EfficiencyDeep Learning