paper-with-me

홈 › Papers

Differential Voltage Analysis and Patterns in Parallel-Connected Pairs of Imbalanced Cells

2024-05-28 · Clement Wong, Andrew Weng, Sravan Pannala, Jeesoon Choi, Jason B. Siegel, Anna Stefanopoulou

Diagnosing imbalances in capacity and resistance within parallel-connected cells in battery packs is critical for battery management and fault detection, but it is challenging given that individual currents flowing into each cell are often unmeasured. This work introduces a novel method useful for identifying imbalances in capacity and resistance within a pair of parallel-connected cells using only voltage and current measurements from the pair. Our method utilizes differential voltage analysis (DVA) when the pair is under constant current discharge and demonstrates that features of the pair's differential voltage curve (dV/dQ), namely its mid-to-high SOC dV/dQ peak's height and skewness, are sensitive to imbalances in capacity and resistance. We analyze and explain how and why these dV/dQ peak shape features change in response to these imbalances, highlighting that the underlying current imbalance dynamics resulting from these imbalances contribute to these changes. Ultimately, we demonstrate that dV/dQ peak shape features can identify the product of capacity imbalance and resistance imbalance, but cannot uniquely identify the imbalances. This work lays the groundwork for identifying imbalances in capacity and resistance in parallel-connected cell groups in battery packs, where commonly only a single current sensor is placed for each parallel cell group.

📄 PDF Abstract BibTeX arXiv:2405.17754

Code (0)

등록된 구현이 없습니다.

Tasks

Fault Detection

Similar Papers 제목 키워드 기반

State of Charge Estimation of Parallel Connected Battery Cells via Descriptor System Theory

2020-03-17

This manuscript presents an algorithm for individual Lithium-ion (Li-ion) battery cell state of charge (SOC) estimation when multiple cells are connected in parallel, using only terminal voltage and total current measure…

Angular Stability Analysis of Parallel Connected Grid-following PV Inverters

2023-04-06 · Ramkrishna Mishan

High penetration of distributed generators (DG) in modern power grids creates angle, voltage, and frequency instabilities. Most of the work in the literature has focused on small-signal stability analysis of single grid-…

Cell-Level State of Charge Estimation for Battery Packs Under Minimal Sensing

2021-09-17 · Dong Zhang, Luis D. Couto, Ross Drummond, Shashank Sripad 외

This manuscript presents an algorithm for individual Lithium-ion (Li-ion) battery cell state of charge (SOC) estimation in a large-scale battery pack under minimal sensing, where only pack-level voltage and current are m…

State of Health Estimation for Battery Modules with Parallel-Connected Cells Under Cell-to-Cell Variations

2023-12-05 · Qinan Zhou, Dyche Anderson, Jing Sun

State of health (SOH) estimation for lithium-ion battery modules with cells connected in parallel is a challenging problem, especially with cell-to-cell variations. Incremental capacity analysis (ICA) and differential vo…

feature selection

A Comparative Analysis of Transformer-less Inverter Topologies for Grid-Connected PV Systems: Minimizing Leakage Current and THD

2025-01-14 · Shashwot Shrestha, Rachana Subedi, Swodesh Sharma, Sushil Phuyal 외

The integration of distributed energy resources (DERs), particularly photovoltaic (PV) systems, into power grids has gained major attention due to their environmental and economic benefits. Although traditional transform…