Electromagnetic Navigation for Femoral Osteotomy Using High-Accuracy X-ray-to-CT Registration
Accurate execution of preoperative plans in corrective femoral osteotomies remains challenging. Current techniques are limited by variable accuracy, invasiveness, and radiation exposure, with free-hand methods and patient-specific instrumentation (PSI) often requiring >30 and >6 fluoroscopic images, respectively. We present an integrated, electromagnetic tracking (EMT)-based navigation system for femoral osteotomies that minimizes dissection and intraoperative fluoroscopy. The system couples CT-based preoperative planning with one-time intraoperative C-arm calibration and accurate X-ray-to-CT registration from two fluoroscopic images acquired at initialization. This enables real-time, fluoroscopy-free EMT navigation of the saw blade and bone fragments relative to the preoperative plan, and is compatible with uniplanar and biplanar osteotomies. In a feasibility study using 18 synthetic femora, EMT guidance significantly outperformed free-hand execution in total angular error ($(3.05 \pm 0.75)^\circ$ vs.\ $(6.32 \pm 2.36)^\circ$, $p=0.031$), assuming the same minimal surgical exposure for both. No EMT-guided trials exceeded the >5° clinical threshold, whereas free-hand produced 4 outliers of 6 trials. The system achieved statistical equivalence ($\pm 2^\circ$, $\pm 2,\text{mm}$) to PSI for total angular ($p \le 0.02$) and total translational ($p=0.048$) errors, with no significant differences in user questionnaire scores. By transferring preoperative plans using only two fluoroscopic images while matching PSI accuracy without additional surgical exposure, the proposed system motivates subsequent cadaveric and clinical validation.
Code (0)
등록된 구현이 없습니다.
Similar Papers 제목 키워드 기반
Patch-Based Image Similarity for Intraoperative 2D/3D Pelvis Registration During Periacetabular Osteotomy
Periacetabular osteotomy is a challenging surgical procedure for treating developmental hip dysplasia, providing greater coverage of the femoral head via relocation of a patient's acetabulum. Since fluoroscopic imaging i…
Pose Estimation of Periacetabular Osteotomy Fragments with Intraoperative X-Ray Navigation
Objective: State of the art navigation systems for pelvic osteotomies use optical systems with external fiducials. We propose the use of X-Ray navigation for pose estimation of periacetabular fragments without fiducials.…
Pose EstimationFast and Automatic Periacetabular Osteotomy Fragment Pose Estimation Using Intraoperatively Implanted Fiducials and Single-View Fluoroscopy
Accurate and consistent mental interpretation of fluoroscopy to determine the position and orientation of acetabular bone fragments in 3D space is difficult. We propose a computer assisted approach that uses a single flu…
Pose EstimationComparative Analysis of Autonomous Robotic and Manual Techniques for Ultrasonic Sacral Osteotomy: A Preliminary Study
In this paper, we introduce an autonomous Ultrasonic Sacral Osteotomy (USO) robotic system that integrates an ultrasonic osteotome with a seven-degree-of-freedom (DoF) robotic manipulator guided by an optical tracking sy…
Depth Camera Based Particle Filter for Robotic Osteotomy Navigation
Active surgical robots lack acceptance in clinical practice, because they do not offer the flexibility and usability required for a versatile usage: the systems require a large installation space or a complicated registr…