paper-with-me

Papers

Reconstruction of Cardiac Cine MRI Using Motion-Guided Deformable Alignment and Multi-Resolution Fusion

2023-03-09 · Xiaoxiang Han, Yang Chen, Qiaohong Liu, Yiman Liu, Keyan Chen, Yuanjie Lin, Weikun Zhang

Cardiac cine magnetic resonance imaging (MRI) is one of the important means to assess cardiac functions and vascular abnormalities. Mitigating artifacts arising during image reconstruction and accelerating cardiac cine MRI acquisition to obtain high-quality images is important. A novel end-to-end deep learning network is developed to improve cardiac cine MRI reconstruction. First, a U-Net is adopted to obtain the initial reconstructed images in k-space. Further to remove the motion artifacts, the motion-guided deformable alignment (MGDA) module with second-order bidirectional propagation is introduced to align the adjacent cine MRI frames by maximizing spatial-temporal information to alleviate motion artifacts. Finally, the multi-resolution fusion (MRF) module is designed to correct the blur and artifacts generated from alignment operation and obtain the last high-quality reconstructed cardiac images. At an 8$\times$ acceleration rate, the numerical measurements on the ACDC dataset are structural similarity index (SSIM) of 78.40%$\pm$.57%, peak signal-to-noise ratio (PSNR) of 30.46$\pm$1.22dB, and normalized mean squared error (NMSE) of 0.0468$\pm$0.0075. On the ACMRI dataset, the results are SSIM of 87.65%$\pm$4.20%, PSNR of 30.04$\pm$1.18dB, and NMSE of 0.0473$\pm$0.0072. The proposed method exhibits high-quality results with richer details and fewer artifacts for cardiac cine MRI reconstruction on different accelerations.

📄 PDF Abstract BibTeX arXiv:2303.04968

Code (0)

등록된 구현이 없습니다.

Tasks

Image ReconstructionMRI ReconstructionSSIM

Methods 이 논문이 사용한 방법론

ReLU How Do I Communicate to Expedia? How Do I Communicate to Expedia? – Call ☎️ +1-(888) 829 (0881) or +1-805-330-4056 or +1-805-330-4056 for Live Support & Special Travel…
Concatenated Skip Connection A Concatenated Skip Connection is a type of skip connection that seeks to reuse features by concatenating them to new layers, allowing more information to be retained from…
Max Pooling Max Pooling is a pooling operation that calculates the maximum value for patches of a feature map, and uses it to create a downsampled (pooled) feature map. It is usually…
ALIGN In the ALIGN method, visual and language representations are jointly trained from noisy image alt-text data. The image and text encoders are learned via contrastive loss…
Convolution A convolution is a type of matrix operation, consisting of a kernel, a small matrix of weights, that slides over input data performing element-wise multiplication with the…
U-Net 설명 없음
SPEED The monocular depth estimation (MDE) is the task of estimating depth from a single frame. This information is an essential knowledge in many computer vision tasks such as scene…

Similar Papers 제목 키워드 기반

Motion-Guided Deep Image Prior for Cardiac MRI

2024-12-05 · Marc Vornehm, Chong Chen, Muhammad Ahmad Sultan, Syed Murtaza Arshad 외

Cardiovascular magnetic resonance imaging is a powerful diagnostic tool for assessing cardiac structure and function. Traditional breath-held imaging protocols, however, pose challenges for patients with arrhythmias or l…

Diagnostic

CardioMorphNet: Cardiac Motion Prediction Using a Shape-Guided Bayesian Recurrent Deep Network

2025-08-28 · Reza Akbari Movahed, Abuzar Rezaee, Arezoo Zakeri, Colin Berry 외 arxiv

Accurate cardiac motion estimation from cine cardiac magnetic resonance (CMR) images is vital for assessing cardiac function and detecting its abnormalities. Existing methods often struggle to accurately capture heart mo…

Image Registration

CNN-based Cardiac Motion Extraction to Generate Deformable Geometric Left Ventricle Myocardial Models from Cine MRI

2021-03-30 · Roshan Reddy Upendra, Brian Jamison Wentz, Richard Simon, Suzanne M. Shontz 외

Patient-specific left ventricle (LV) myocardial models have the potential to be used in a variety of clinical scenarios for improved diagnosis and treatment plans. Cine cardiac magnetic resonance (MR) imaging provides hi…

Image RegistrationMotion Estimation

CineMesh4D: Personalized 4D Whole Heart Reconstruction from Sparse Cine MRI

2026-05-13 · Xiaoyue Liu, Xiaohan Yuan, Mark Y Chan, Ching-Hui Sia 외 arxiv

Accurate 3D+t whole-heart mesh reconstruction from cine MRI is a clinically crucial yet technically challenging task. The difficulty of this task arises from two coupled factors: inherently sparse sampling of 3D cardiac …

DMCVR: Morphology-Guided Diffusion Model for 3D Cardiac Volume Reconstruction

2023-08-18 · Xiaoxiao He, Chaowei Tan, Ligong Han, Bo Liu 외

Accurate 3D cardiac reconstruction from cine magnetic resonance imaging (cMRI) is crucial for improved cardiovascular disease diagnosis and understanding of the heart's motion. However, current cardiac MRI-based reconstr…

3D Reconstruction