Physics-informed Score-based Diffusion Model for Limited-angle Reconstruction of Cardiac Computed Tomography
Cardiac computed tomography (CT) has emerged as a major imaging modality for the diagnosis and monitoring of cardiovascular diseases. High temporal resolution is essential to ensure diagnostic accuracy. Limited-angle data acquisition can reduce scan time and improve temporal resolution, but typically leads to severe image degradation and motivates for improved reconstruction techniques. In this paper, we propose a novel physics-informed score-based diffusion model (PSDM) for limited-angle reconstruction of cardiac CT. At the sampling time, we combine a data prior from a diffusion model and a model prior obtained via an iterative algorithm and Fourier fusion to further enhance the image quality. Specifically, our approach integrates the primal-dual hybrid gradient (PDHG) algorithm with score-based diffusion models, thereby enabling us to reconstruct high-quality cardiac CT images from limited-angle data. The numerical simulations and real data experiments confirm the effectiveness of our proposed approach.
Code (1)
Tasks
Computed Tomography (CT)DiagnosticMethods 이 논문이 사용한 방법론
Similar Papers 제목 키워드 기반
Physics-Informed Diffusion Models for Unsupervised Anomaly Detection in Multivariate Time Series
We propose an unsupervised anomaly detection approach based on a physics-informed diffusion model for multivariate time series data. Over the past years, diffusion model has demonstrated its effectiveness in forecasting,…
Unsupervised Anomaly DetectionPhysics-Informed Diffusion for Biomechanically Plausible 3D Sign Language Generation
Sign language production, which generates continuous 3D skeletal motion from spoken language input, must simultaneously satisfy two constraints: semantic fidelity, so that a deaf viewer can recognize the intended sequenc…
Physics-Informed Spectral Modeling for Hyperspectral Imaging
We present PhISM, a physics-informed deep learning architecture that learns without supervision to explicitly disentangle hyperspectral observations and model them with continuous basis functions. PhISM outperforms prior…
PET-Adapter: Test-Time Domain Adaptation for Full and Limited-Angle PET Image Reconstruction
Positron Emission Tomography (PET) image reconstruction is inherently challenged by Poisson noise and physical degradation factors, which are further exacerbated in limited-angle acquisitions. While deep learning methods…
Computational EfficiencyImage Reconstruction3D ReconstructionDomain AdaptationRiemannian Diffusion Models on General Manifolds via Physics-Informed Neural Networks
Riemannian diffusion models generalize score-based generative modeling to manifold-supported data via stochastic diffusion equations on the manifold. However, training requires sampling from and differentiating the manif…
Point Clouds