Motion Informed Needle Segmentation in Ultrasound Images
Segmenting a moving needle in ultrasound images is challenging due to the presence of artifacts, noise, and needle occlusion. This task becomes even more demanding in scenarios where data availability is limited. In this paper, we present a novel approach for needle segmentation for 2D ultrasound that combines classical Kalman Filter (KF) techniques with data-driven learning, incorporating both needle features and needle motion. Our method offers three key contributions. First, we propose a compatible framework that seamlessly integrates into commonly used encoder-decoder style architectures. Second, we demonstrate superior performance compared to recent state-of-the-art needle segmentation models using our novel convolutional neural network (CNN) based KF-inspired block, achieving a 15\% reduction in pixel-wise needle tip error and an 8\% reduction in length error. Third, to our knowledge we are the first to implement a learnable filter to incorporate non-linear needle motion for improving needle segmentation.
Code (0)
등록된 구현이 없습니다.
Tasks
DecoderSegmentationSimilar Papers 제목 키워드 기반
A temporal enhanced semi-supervised segmentation network for needle detection in 3D ultrasound images
Objective. Automated biopsy needle segmentation in 3D ultrasound images can be used for biopsy navigation, but it is quite challenging due to the low ultrasound image resolution and interference similar to the needle app…
Image SegmentationMedical Image SegmentationPositionSegmentation+1Nerve Block Target Localization and Needle Guidance for Autonomous Robotic Ultrasound Guided Regional Anesthesia
Visual servoing for the development of autonomous robotic systems capable of administering UltraSound (US) guided regional anesthesia requires real-time segmentation of nerves, needle tip localization and needle trajecto…
Anatomyobject-detectionObject DetectionObject Tracking+1ConVibNet: Needle Detection during Continuous Insertion via Frequency-Inspired Features
Purpose: Ultrasound-guided needle interventions are widely used in clinical practice, but their success critically depends on accurate needle placement, which is frequently hindered by the poor and intermittent visibilit…
Vibration-Based Energy Metric for Restoring Needle Alignment in Autonomous Robotic Ultrasound
Precise needle alignment is essential for percutaneous needle insertion in robotic ultrasound-guided procedures. However, inherent challenges such as speckle noise, needle-like artifacts, and low image resolution make ro…
Enhanced Uncertainty Estimation in Ultrasound Image Segmentation with MSU-Net
Efficient intravascular access in trauma and critical care significantly impacts patient outcomes. However, the availability of skilled medical personnel in austere environments is often limited. Autonomous robotic ultra…
Image SegmentationSegmentationSemantic Segmentation